Feasibility, Reliability, and Convergent Validity of the Five Times Sit-to-Stand Test via Telehealth in Multiple Sclerosis.
Erin Lampron, Laura Simaitis, Natalie Armstrong, Rhianna Moriarty, Sarah Passaretti, Hannah Stamm, Elizabeth S Gromisch, Heather M DelMastro
Department of Physical Therapy, School of Health Sciences at Quinnipiac University, North Haven, CT. · From the Joyce D. and Andrew J. Mandell Center for Comprehensive Multiple Sclerosis Care and Neuroscience Research, Mount Sinai Rehabilitation Hospital, Trinity Health Of New England, Hartford, CT, USA (HMDM, JAR, ESG, LON, ACL).
Key points
From the paper's conclusion- The rFTSTS is feasible, safe, and reliable, and exhibits convergent validity with hip and knee strength. While further validation is needed, the rFTSTS may be a useful measure for telerehabilitation in people with MS with mild to moderate impairment.
Abstract
BACKGROUND: Physical therapy via telehealth for people with multiple sclerosis (MS) may be a feasible mode of delivery to improve accessibility and continuity of care. However, little evidence exists to guide the selection of tests and measures in telerehabilitation. This study aimed to confirm the reliability and examine the feasibility, safety, and convergent validity of the remote Five Times Sit-to-Stand (rFTSTS) test among people with MS. METHODS: Demographics, disease characteristics, in-person Five Times Sit-to-Stand (FTSTS) and rFTSTS, and hip and knee isometric strength were collected on people with MS (N = 32) at a one-time visit. The rFTSTS and FTSTS were administered concurrently. Inter-rater reliability between rFTSTS and FTSTS was assessed using a 2-way random effect, single measurement intraclass coefficient (ICC). Spearman rank correlations (ρ) were used to determine the association between rFTSTS and knee and hip strength. RESULTS: The rFTSTS and FTSTS had excellent inter-rater reliability (ICC= 1.00, P <. 001), and were easy to administer without adverse events. The rFTSTS exhibited moderate to large associations (P < .05) with the strongest and weakest limb's hip flexion (strongest: ρ = 0.449; weakest: ρ = 0.474) and extension (strongest: ρ = 0.378; weakest: ρ = 0.362) and the weakest limb's knee flexion (ρ = 0.552) and extension (ρ = 0.427). CONCLUSIONS: The rFTSTS is feasible, safe, and reliable, and exhibits convergent validity with hip and knee strength. While further validation is needed, the rFTSTS may be a useful measure for telerehabilitation in people with MS with mild to moderate impairment.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Pilot Study of Smartphone-Based Neuroperformance Tests in Multiple Sclerosis.International journal of MS care · 2026
- Remote Asynchronous Smartphone 5 Times Sit-to-Stand Testing in Older Adults: Pragmatic Validity Trial.JMIR aging · 2026
- Construct validity and intrasession intra-rater reliability of the stair and step tests in individuals with multiple sclerosis.Physiotherapy theory and practice · 2026
- Protocol for a pilot effectiveness and feasibility randomized controlled trial of an advanced telerehabilitation system for people with multiple sclerosis (PLATINUMS project).PloS one · 2026
- Primary results of the supervised versus telerehabilitation exercise program for multiple sclerosis trial: A comparative effectiveness trial.Multiple sclerosis (Houndmills, Basingstoke, England) · 2026
- A New Protocol for Evaluating Maximum Respiratory Pressures in Individuals With Multiple Sclerosis: Concurrent Validity and Test-Retest Reliability.Journal of neurologic physical therapy : JNPT · 2026