International journal of MS care

Pilot Study of Smartphone-Based Neuroperformance Tests in Multiple Sclerosis.

Katherine Beshears, Mengke Du, Mandy Koop, Kelsey Owen, Jay Alberts, Marisa P McGinley

Cleveland Clinic Lerner College of Medicine, Cleveland, OH. · Department of Quantitative Health Sciences, Cleveland Clinic Lerner Research Institute, Cleveland, OH.

Key points

From the paper's conclusion
  • The FTT, PST, rTUG, and r5STS performed via smartphone application demonstrate convergent validity with their analogous MSPT tests. Open-eye balance outcomes also show promise for use in people with MS. These smartphone-based tests may allow for remote measurement of function for people with MS.

Abstract

BACKGROUND: The Multiple Sclerosis Functional Composite and its iPad-based companion, the Multiple Sclerosis Performance Test (MSPT), as well as other traditional function tests must be performed during a clinic visit, which presents challenges for some people with multiple sclerosis (MS). METHODS: Smartphone tests were developed, including a remote Timed Up and Go (rTUG), remote 5 Times Sit-to-Stand (r5STS), finger tapping test (FTT), and processing speed test (PST), in addition to open- and closed-eye balance measures. People with MS and a control group (CG) without MS performed smartphone tests and the previously validated, iPad-based MSPT. Convergent validity, sensitivity to disease status, and test-retest reliability were assessed. RESULTS: The CG (n = 23; mean age, 38.56 ± 18.5 years; 65% female; 74% White) and the MS group (n = 23; mean age, 58.5 ± 11.9 years; 48% female; 83% White; mean disease duration, 11.82 ± 6.72 years) completed tests at a single visit. Valid taps per second on FTT was moderately correlated with the manual dexterity test (Spearman correlation coefficients, ρ = -0.46 [right] and -0.41 [left]). Total number correct on smartphone-administered PST strongly correlated with iPad-administered PST (ρ = 0.78). rTUG had a strong correlation and r5STS had a moderate correlation with the Timed 25-Foot Walk test (ρ = 0.80 and 0.55, respectively). Ellipse volume and ellipse area, derived from open-eye balance tests, showed sensitivity to disease status (partial η2 = 0.08 and 0.07, respectively) and good test-retest reliability (intraclass correlation coefficient = 0.82 and 0.77, respectively). CONCLUSIONS: The FTT, PST, rTUG, and r5STS performed via smartphone application demonstrate convergent validity with their analogous MSPT tests. Open-eye balance outcomes also show promise for use in people with MS. These smartphone-based tests may allow for remote measurement of function for people with MS.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers