Literature-Grounded Simulation of Non-Invasive Glucose Monitoring Using NIR Wearable Sensor Archetypes: Accuracy Metrics, Candidate Confounders, and an Adaptive Calibration Framework.
David Alberto García-Arango, José Alexander Velásquez Ochoa, Luis Fernando Garcés Giraldo, Natalia Isabel Jaramillo Gómez
Research Directorate, Universidad Autónoma del Perú, Villa EL Salvador, Lima 15042, Peru. · Research Departament, Tecnológico de Antioquia, Medellín 050036, Colombia.
Key points
From the paper's conclusion- This study was revised as a literature-grounded simulation and methodological proof-of-concept rather than an experimental clinical validation.
Abstract
Non-invasive continuous glucose monitoring remains an important technological challenge in diabetes management. This study was revised as a literature-grounded simulation and methodological proof-of-concept rather than an experimental clinical validation. The analysis used 320 independent synthetic reference-NIR glucose pairs generated from physiological ranges and performance distributions reported in the cited literature, together with an illustrative 576-point, 48-h synthetic time series. Three sensor archetypes were informed by published optical systems. Descriptive agreement was evaluated using mean absolute relative difference (MARD), Pearson correlation, Bland-Altman analysis, and the supplied Clarke Error Grid (CEG) categories. Candidate physiological and environmental factors were examined using Pearson correlations with 95% confidence intervals, raw p-values, and Holm correction. The synthetic dataset produced an overall MARD of 10.38% (SD = 7.67%), r = 0.958 (R2 = 0.918, p < 0.001), a Bland-Altman bias of 4.32 mg/dL, and 89.4%/10.3%/0.3% of records in CEG zones A/B/D, respectively. All candidate-factor correlations were small and non-significant after multiplicity correction; the largest was hematocrit (r = 0.090, 95% CI -0.019 to 0.198; Holm-adjusted p = 0.852). Differences in MARD among sensor archetypes were also non-significant (ANOVA p = 0.369; Kruskal-Wallis p = 0.543). Adaptive calibration is therefore presented as a literature-informed framework for future prospective validation, not as a performance improvement demonstrated by the present synthetic dataset. No FDA or ISO compliance or clinical applicability is claimed.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Non-Invasive Blood Glucose Monitoring Using Machine Learning and Optical Approaches: A Systematic Literature Review and a Proposed Framework for Reproducible and Clinically Reliable Research.Sensors (Basel, Switzerland) · 2026
- Non-invasive blood glucose detection system using combined visible and near-infrared spectral dataScientific Reports · 2026
- Uncertainty-aware fourier-encoded attentive Bi-GRU for non-invasive blood glucose estimation from multimodal PPG and GSR signals.Frontiers in medical technology · 2026
- Clinical validation of noninvasive blood glucose measurements by midinfrared spectroscopyCommunications Medicine · 2025
- Real-World Evaluation of a Near-Infrared Spectroscopy-based Noninvasive Glucose Monitoring Device in Adults With Type 2 Diabetes.Journal of diabetes science and technology · 2026
- Adaptive personalization for wearable non-invasive continuous glucose sensors.Nature communications · 2026