Near point of care C-Reactive Protein and Serum Amyloid-A Test met WHO target product profile for TB screening
T. P. Setiabudiawan, N. Iswandari, M. Korompis, R. C. Koesoemadinata, E. Susandi, I. D. Kulsum, D. K. Turbawaty, B. Alisjahbana
Key points
From the paper's conclusion- This study investigated the diagnostic accuracy of C-reactive protein (CRP), serum amyloid A (SAA), and interferon gamma-induced protein 10 (IP-10) as potential screening tools.
Abstract
BackgroundTB eradication strategies in high burden countries need affordable, scalable, and accessible screening tools. This study investigated the diagnostic accuracy of C-reactive protein (CRP), serum amyloid A (SAA), and interferon gamma-induced protein 10 (IP-10) as potential screening tools.
MethodThis cross-sectional diagnostic study investigated stored archived serum samples from three groups of subjects; bacteriology confirmed symptomatic TB group (n=57), probable TB (n=56) and healthy controls (n=60). CRP and SAA concentrations were measured using near point-of-care fluorescence immunoassay (NPOCT-FIA), while IP-10 was measured using enzyme-linked immunosorbent assay (ELISA). Diagnostic performance of individual and combined biomarkers was evaluated
ResultsReceiver operating characteristic analysis demonstrated excellent diagnostic performance of serum amyloid A (SAA) and C-reactive protein (CRP) for identifying confirmed tuberculosis (TB). Compared with probable TB and healthy controls, SAA achieved an AUC of 0.961 (cut-off >31.0 mg/L), with 96.5% sensitivity and 88.6% specificity, while CRP achieved an AUC of 0.953 (cut-off 21.3 mg/L), with 96.5% sensitivity and 86.0% specificity. Interferon gamma-induced protein 10 (IP-10) showed poor discrimination (AUC 0.545). Combined CRP and SAA achieved 100.0% sensitivity and 83.3% specificity.
ConclusionSAA and CRP met WHO target product profile criteria for TB triage screening.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparative cost analysis of community-based tuberculosis screening: Computer-Aided Detection (CAD) alone versus CAD with point-of-care C-reactive protein testing in South Africa and Lesotho.PLOS global public health · 2026
- A-064 Predictive algorithm of serum Adenosine Deaminase, Retinol, hsCRP and Lactate Dehydrogenase in diagnosis of Pulmonary TuberculosisClinical Chemistry · 2026
- Diagnostic accuracy of a novel point-of-care tongue swab assay for pulmonary tuberculosis: a multicentre prospective studyClinical Microbiology and Infection · 2025
- Bioinspired trimetallic optimised Bi(0.10)CuFe2O4 nanoparticle-based interface for selective and sensitive impedimetric detection of C-reactive protein for tuberculosis monitoring.Talanta · 2026
- Diagnostic value of lesion-targeted BALF immune biomarkers combined with T-SPOT.TB for smear-negative pulmonary tuberculosis.Microbiology spectrum · 2026
- Diagnostic Accuracy of the Three-Gene Host-Response Test in Blood for Tuberculosis: A Systematic Review.International journal of microbiology · 2026