科研速览 · Science Skim继续刷下去 · Keep skimming →
◆ Clinical Microbiology and Infection2025-11-20· Medicine

Diagnostic accuracy of a novel point-of-care tongue swab assay for pulmonary tuberculosis: a multicentre prospective study

Zhuhua Wu, Yan Li, Xiaoyu Lai, Jiong Yang, Jing Liang, Xinhua Ma, Jianhong Xie, Liwei Ji, Yong Wang, Jianzhong Hu, Ruiming Chen, Chunfang Lv, Xiao Fu, Yuhui Chen, Huixin Guo, Liuyue Xu, Hongdi Liang, Sheng‐Yuan Liu, Zhuanghao Chen, Mingxing Huang, Xinguang Zhong, Xunxun Chen

原始摘要(英文原文)· Original abstract
OBJECTIVES: Tuberculosis (TB) remains a leading cause of infectious disease deaths, with underdiagnosis driving ongoing transmission. We evaluated the diagnostic performance of the MiniDock MTB Test (MiniDock), an innovative point-of-care testing molecular system, using tongue swab and sputum specimens. METHODS: This prospective multicentre study enrolled 594 participants with suspected symptomatic pulmonary TB across seven TB hospitals in Guangdong Province. Tongue swabs and sputum samples were tested using MiniDock system of Pluslife. Sputum specimens were evaluated with Xpert MTB/RIF (Xpert), smear microscopy, and mycobacteria growth indicator tube culture. The diagnostic performance of MiniDock was compared with that of mycobacteria growth indicator tube culture and sputum Xpert findings. Diagnostic performance was compared against a composite microbiological reference standard (MRS). RESULTS: The sputum MiniDock demonstrated sensitivity and specificity of 98.2% (95% CI, 95.7-99.2%) and 90.4% (95% CI, 86.7-93.2%), compared with sputum Xpert, and 94.2% (95% CI, 90.9-96.6%) and 93.7% (95% CI, 90.3-96.1%) compared with the MRS. The MiniDock test with tongue swabs had a sensitivity of 80.0% (95% CI, 74.8-84.3%) and a specificity of 95.4% (95% CI, 92.5-97.2%) compared with sputum Xpert, and 74.5% (95% CI, 69.1-79.4%) and 96.0% (95% CI, 93.1-97.9%) compared with the MRS. The sensitivity of tongue swab MiniDock varied by bacterial load, ranging from 98.2% (95% CI, 90.2-99.7%) in high-load samples to 47.8% (95% CI, 29.2-67.0%) in very-low-load samples; for sputum samples, the corresponding sensitivities were 100% (95% CI, 93.4-100.0%) and 87.0% (95% CI, 67.9-95.5%), respectively. CONCLUSIONS: The MiniDock test using tongue swabs and sputum provides a rapid, reliable, and noninvasive point-of-care testing diagnostic option for TB. Although the tongue swab MiniDock has lower sensitivity, its high acceptability makes it a valuable supplementary tool for individuals unable to produce sputum.
读原文 · Read the paper ↗

AI 追问PRO

登录后使用 AI 追问

讨论区

登录后参与讨论

相关论文 · Related

Diagnostic accuracy of a novel point-of-care tongue swab assay for pulmonary tuberculosis: a multicentre prospective study — 科研速览 Science Skim