Bioinspired trimetallic optimised Bi(0.10)CuFe2O4 nanoparticle-based interface for selective and sensitive impedimetric detection of C-reactive protein for tuberculosis monitoring.
Astha Singh, Siddhima Singh, Neelottma Singh, Jay Singh
Sam Higginbottom University of Agriculture, Technology and Sciences, Prayagraj, 211007, Uttar Pradesh, India. · Sam Higginbottom University of Agriculture, Technology and Sciences, Prayagraj, 211007, Uttar Pradesh, India. Electronic address: neelottma.singh@shiats.edu.in.
Key points
From the paper's conclusion- In this study, we present the development of a sensitive electrochemical CRP detection platform based on Bi(0.10)CuFe2O4 trimetallic nanoparticles produced via an environmentally safe green hydrothermal technique using Magnolia grandiflora leaf extract.
Abstract
Tuberculosis (TB) is still a major global health problem, and early detection, assessment of treatment response, and disease management depend heavily on reliable monitoring systems. C-reactive protein (CRP), an acute-phase inflammatory biomarker, provides valuable insights into the progression of TB and therapeutic outcomes. In this study, we present the development of a sensitive electrochemical CRP detection platform based on Bi(0.10)CuFe2O4 trimetallic nanoparticles produced via an environmentally safe green hydrothermal technique using Magnolia grandiflora leaf extract. The structure and properties were thoroughly characterised using FT-IR, X-ray diffraction (XRD), SEM, UV, EDX, and HR-TEM. These trimetallic nanoparticles (TMNPs) provide efficient approaches for developing advanced biosensing platforms, particularly for detecting the C-reactive protein (CRP) biomarker associated with tuberculosis. Electrochemical analysis was conducted employing Cyclic Voltammetry (CV) and Electrochemical Impedance Spectroscopy (EIS). The linear concentration range is 0.5-100 ng/mL, with a limit of detection (LOD) of 0.0352 ng/mL. The regression coefficient is 0.98696, and the sensitivity is 4.03088 Ω/ng·cm-1. The sensor exhibits high selectivity and sensitivity, with a maximum response time of 20 s. It is cost-effective and holds promise for future applications in medicine.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Near point of care C-Reactive Protein and Serum Amyloid-A Test met WHO target product profile for TB screeningmedRxiv · 2026
- Tuberculosis biomarker detection using the intrinsic photoluminescence of carbonated hydroxyapatite nanoparticles.Talanta · 2026
- Detection of unamplified mycobacterium tuberculosis genomic DNA in sputum samples using a metal-enhanced fluorescence-based biosensor.Mikrochimica acta · 2026
- Rapid PCR-free detection of paucibacillary mycobacteria using nanoparticle-enabled phenomics-to-genomic biosensing assay.Journal of biological engineering · 2026
- Targeted detection of Mycobacterium tuberculosis MPT64 antigen using an antibody-coated nanoporous anodic alumina biosensor: A novel approach for tuberculosis screeningTalanta · 2026
- Optimized Vacuum-Sputtered Gold Nanoparticle-Modified Titanium Dioxide Nanotubes for Ultrasensitive Myocardial Infarction Multi-Biomarker Detection.ACS biomaterials science & engineering · 2026