Optimisation and Validation of a UHPLC-MS/MS Assay Using Timed Post-Column Ammonium Fluoride Infusion for Sensitive Serum Steroids Quantitation
V. Dosedelova, J. M. Hawley, E. Melson, L. Schiffer, K.-H. Storbeck, W. Arlt
Key points
From the paper's conclusion- Thus, to optimise sensitivity, a timed post-column infusion of 2 mmol/L ammonium fluoride was employed during chromatographic separation.
Abstract
Steroid metabolomics has potential for identifying biomarkers and improving disease diagnosis. However, poor ionisation efficiency and low circulating concentrations of some steroids limit the broader clinical applications. Here, we developed a ultra-high-performance liquid chromatography - tandem mass spectrometry (UHPLC-MS/MS) assay for quantitation of 18 steroids in serum encompassing the mineralocorticoid, glucocorticoid and androgen biosynthesis pathways, including both classic and 11-oxygenated androgens. Steroid extraction from 100 L of serum was performed using supported liquid extraction with ethyl acetate elution. Ionisation efficiency of steroids was investigated using formic acid in the mobile phase and post-column infusion of ammonium fluoride. Ammonium fluoride enhanced the signal intensity of 3-keto-{Delta}4 steroids up to ninefold, however A-ring reduced steroids exhibited greater ionisation with formic acid. Thus, to optimise sensitivity, a timed post-column infusion of 2 mmol/L ammonium fluoride was employed during chromatographic separation. The lower limits of quantitation ranged from 0.04 to 2.1 nmol/L. Accuracy ranged from 82 to 113% and intra- and inter-assay imprecision was <10% and <13%, respectively. The assay was applied to analyse morning serum steroid concentrations in healthy individuals (55 women, 44 men; age-matched). Serum progesterone, 11-deoxycorticosterone, dehydroepiandrosterone and androstenedione were significantly higher in women; in contrast, testosterone and 5-dihydrotestosterone were higher in men. In summary, we have successfully developed and validated a UHPLC-MS/MS assay for multi-steroid profiling ad applied it to healthy individuals of both sexes.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Development and validation of a comprehensive mass spectrometry method for the determination of steroids in multi-matrixJournal of Chromatography Open · 2026
- Analytical strategies for distinguishing endogenous and exogenous anabolic androgenic steroids in doping control.Analytical methods : advancing methods and applications · 2026
- Automated enzymatic hydrolysis-magnetic-bead-assisted sequential extraction workflow for LC-MS/MS profiling of urinary aldosterone-pathway steroids.Talanta · 2026
- B-338 Magnetic Bead–Based Sample Preparation for LC–MS/MS Quantification of Steroid Hormones Using PEP Polymer beadsClinical Chemistry · 2026
- B-344 Enhanced Ultra Sensitive Measurement of Serum Estrogens Using the Xevo TQ Absolute XR with UHPLC MS/MS for Clinical Research ApplicationsClinical Chemistry · 2026
- Detection of estrogens using 2-furoyl chloride derivatization coupled with ultra-high-performance liquid chromatography-quadrupole time-of-flight mass spectrometry.Journal of chromatography. A · 2026