B-338 Magnetic Bead–Based Sample Preparation for LC–MS/MS Quantification of Steroid Hormones Using PEP Polymer beads
Massi Chamanian
Key points
From the paper's conclusion- To address these limitations, an LC–MS/MS workflow utilizing PEP magnetic beads for sample preparation was developed to simultaneously quantify eight clinically relevant steroid hormones in serum Methods PEP MagBeads were used to extract testosterone, progesterone, 11 deoxycortisol, corticosterone, androstenedione, desoxycorticosterone (DOC), dehydroepiandrosterone (DHEA), and pregnenolone from 20
Abstract
Background Steroid hormones play essential roles in endocrine regulation, reproductive function, immune balance, and metabolic processes. Abnormal steroid profiles are associated with conditions such as congenital adrenal hyperplasia, polycystic ovary syndrome, and adrenal dysfunction. Traditional immunoassays (RIA/ELISA) often suffer from cross reactivity and inaccurate quantification at low concentrations. To address these limitations, an LC–MS/MS workflow utilizing PEP magnetic beads for sample preparation was developed to simultaneously quantify eight clinically relevant steroid hormones in serum Methods PEP MagBeads were used to extract testosterone, progesterone, 11 deoxycortisol, corticosterone, androstenedione, desoxycorticosterone (DOC), dehydroepiandrosterone (DHEA), and pregnenolone from 200 µL serum. Samples were acidified, loaded onto activated magnetic beads, washed with 2% formic acid, and eluted using anhydrous ethanol prior to LC–MS/MS injection. Chromatographic separation was performed on a Kinetex 2.6 µm C18 3×100 mm column, using ammonium fluoride–methanol gradients. MS/MS detection employed MRM in ESI+ mode with compound specific DP and CE optimization. Calibration curves were prepared in defatted bovine serum using matrix matched standards. Results All eight steroid hormones exhibited excellent linearity across their respective ranges, with correlation coefficients R² = 0.9942, and multiple analytes achieving R² = 1.0000 (testosterone, 11-deoxycortisol, corticosterone). Matrix-spiked bovine serum (2–80 ng/mL) demonstrated strong recovery performance, with average recoveries ranging from 74.6% to 96.9% and precision RSD = 6.6% (n=9). Chromatograms of matrix blanks, standards, and spiked serum showed effective removal of endogenous interferences and clear ion-pair transitions for all target analytes Conclusion PEP MagBeads provide a robust and efficient magnetic SPE platform for LC–MS/MS quantification of steroid hormones. The method demonstrates high linearity, reproducible recoveries, and strong matrix cleanup, supporting its applicability for clinical and research settings requiring accurate steroid profiling. The simplified preparation workflow and magnetic separation format also make the method suitable for high-throughput or automated laboratory environments
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Development and validation of a comprehensive mass spectrometry method for the determination of steroids in multi-matrixJournal of Chromatography Open · 2026
- A Heating-Assisted Integrated Purification-Enrichment-Derivatization Paper Chip for Rapid MS/MS Quantification of Serum Steroid Hormones.Analytical chemistry · 2026
- Extensive Quantitative Profiling of Plasma Steroidome and Prostaglandin Metabolites for Studies of Female Reproductive Physiology.Analytical chemistry · 2026
- Optimisation and Validation of a UHPLC-MS/MS Assay Using Timed Post-Column Ammonium Fluoride Infusion for Sensitive Serum Steroids QuantitationbioRxiv · 2026
- Automated enzymatic hydrolysis-magnetic-bead-assisted sequential extraction workflow for LC-MS/MS profiling of urinary aldosterone-pathway steroids.Talanta · 2026
- Preliminary analytical evaluation of the fully automated Cobas i601 LC-MS/MS system for steroid hormones and vitamin D in a clinical laboratory.Clinica chimica acta; international journal of clinical chemistry · 2026