  • A digital workflow incorporating intraoral scanning and an auxiliary occlusal device was associated with improved occlusal accuracy, optimized occlusal force distribution, reduced laboratory time, and fewer occlusal adjustments compared to a conventional workflow for posterior implant-supported single crowns.

Abstract

OBJECTIVES: To compare the effects of a digital workflow versus a conventional workflow on occlusal contacts of posterior implant-supported single crowns using digital occlusal analysis. METHODS: This retrospective study included 239 patients with single posterior implant-supported monolithic zirconia crowns, comprising a digital workflow group (DWG, n = 101) and a conventional workflow group (CWG, n = 138). In the DWG, intraoral scanning with an auxiliary occlusal device and computer-aided design/computer-aided manufacturing (CAD/CAM) were performed without using stone casts, while the CWG used polyether impressions and stone cast fabrication. Occlusal deviation parameters, relative occlusal force (ROF) measured by the T-Scan III system, time efficiency, and clinical adjustments were evaluated at crown insertion and at 6-month follow-up. RESULTS: Compared to the CWG, the DWG showed significantly lower maximum occlusal deviation, mean occlusal deviation, occlusal adjustment area, and occlusion time ratio (all P < 0.001). The ROF of the implant crown was lower (P = 0.004), whereas the ROF of the adjacent natural tooth was higher (P = 0.002) in the DWG. In addition, the DWG showed significantly shorter total laboratory time (P < 0.001) and impression/scan time (P < 0.001), as well as fewer crowns requiring occlusal adjustment (P = 0.012). CONCLUSIONS: A digital workflow incorporating intraoral scanning and an auxiliary occlusal device was associated with improved occlusal accuracy, optimized occlusal force distribution, reduced laboratory time, and fewer occlusal adjustments compared to a conventional workflow for posterior implant-supported single crowns.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Influence of a digital versus a conventional workflow on occlusal contacts of posterior implant-supported single crowns based on digital occlusal analysis: a retrospective study — Science Skim