Influence of a digital versus a conventional workflow on occlusal contacts of posterior implant-supported single crowns based on digital occlusal analysis: a retrospective study.
Huaxin Sui, Zheng He, Hongyu Fu
Department of Stomatology, Peking University First Hospital Beijing 100034, China.
Key points
From the paper's conclusion- A digital workflow incorporating intraoral scanning and an auxiliary occlusal device was associated with improved occlusal accuracy, optimized occlusal force distribution, reduced laboratory time, and fewer occlusal adjustments compared to a conventional workflow for posterior implant-supported single crowns.
Abstract
OBJECTIVES: To compare the effects of a digital workflow versus a conventional workflow on occlusal contacts of posterior implant-supported single crowns using digital occlusal analysis. METHODS: This retrospective study included 239 patients with single posterior implant-supported monolithic zirconia crowns, comprising a digital workflow group (DWG, n = 101) and a conventional workflow group (CWG, n = 138). In the DWG, intraoral scanning with an auxiliary occlusal device and computer-aided design/computer-aided manufacturing (CAD/CAM) were performed without using stone casts, while the CWG used polyether impressions and stone cast fabrication. Occlusal deviation parameters, relative occlusal force (ROF) measured by the T-Scan III system, time efficiency, and clinical adjustments were evaluated at crown insertion and at 6-month follow-up. RESULTS: Compared to the CWG, the DWG showed significantly lower maximum occlusal deviation, mean occlusal deviation, occlusal adjustment area, and occlusion time ratio (all P < 0.001). The ROF of the implant crown was lower (P = 0.004), whereas the ROF of the adjacent natural tooth was higher (P = 0.002) in the DWG. In addition, the DWG showed significantly shorter total laboratory time (P < 0.001) and impression/scan time (P < 0.001), as well as fewer crowns requiring occlusal adjustment (P = 0.012). CONCLUSIONS: A digital workflow incorporating intraoral scanning and an auxiliary occlusal device was associated with improved occlusal accuracy, optimized occlusal force distribution, reduced laboratory time, and fewer occlusal adjustments compared to a conventional workflow for posterior implant-supported single crowns.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- The Impact of Digital Workflows on the Design of Fixed Prostheses: A Systematic Literature Review.Clinical, cosmetic and investigational dentistry · 2026
- Comparative Evaluation of Conventional and Digital Workflow Impressions for Implant-Supported RestorationsDentistry Journal · 2026
- Model-free digital-correction workflow for multi-implant restorations: A clinical proof-of-concept study.Journal of prosthodontic research · 2026
- Retrospective analysis of CAD-CAM occlusal devices.The Journal of prosthetic dentistry · 2026
- Manufacturing trueness, internal fit, and planned-to-intraoral spatial concordance of monolithic zirconia crowns fabricated with two commercial ti-base systems: a clinical cross-sectional study.BMC oral health · 2026
- Implant Position Accuracy of a Dual-Function Bite Holder for Single-Visit Registration of Complete-Arch Implants and Maxillomandibular Relationship: An In Vitro Study.The International journal of oral & maxillofacial implants · 2026