Conjunctiva-scleral thickness over the Ahmed glaucoma valve tube in eyes at clinically suspected risk of tube exposure: Anterior segment optical coherence tomography findings.
Fatma Isil Sozen-Delil, Raziye Dönmez Gün
Department of Ophthalmology, Kartal Dr. Lutfi Kirdar City Hospital, Istanbul, Turkey.
Key points
From the paper's conclusion- In this preselected high-risk cohort, a modest inverse correlation was observed between post-operative follow-up duration and conjunctiva-scleral thickness overlying the tube; however, this association was not consistently demonstrated across analytical approaches and should therefore be considered exploratory. Anterior segment optical coherence tomography allows objective characterization of tissue coverage over the Ahmed glaucoma valve tube. Further prospective studies with larger cohorts and appropriate control groups are warranted to determine the clinical significance of these findings.
Abstract
PURPOSE: To characterize conjunctiva-scleral thickness over the Ahmed glaucoma valve tube in eyes clinically considered to be at increased risk of tube exposure based on a superficially positioned tube on anterior segment optical coherence tomography, and to explore the association between post-operative follow-up duration and conjunctiva-scleral thickness. METHODS: This retrospective study included 22 eyes of 21 patients with 23 Ahmed glaucoma valve tubes. One patient contributed both eyes, and another had two Ahmed glaucoma valve tubes in one eye. All eyes had a minimum post-operative follow-up of 6 months and a clinically apparent superficial tube trace on slit-lamp examination. Over-the-tube conjunctiva-scleral thickness and total conjunctiva-scleral thickness were measured at corresponding locations using anterior segment optical coherence tomography. Associations between conjunctiva-scleral thickness measurements and post-operative follow-up duration were evaluated using correlation analysis and generalized estimating equation models to account for clustering. RESULTS: The mean age was 56 ± 12 years (range, 38-80 years). Best-corrected visual acuity was 1.00 (range, 0.10-3.00) LogMAR, and intraocular pressure was 16 (range, 7-27)mmHg. The median post-operative follow-up duration was 40 months (range, 6-135 months), and the median CST overlying the tube at its most superficial location was 190 μm (range, 54-552 μm). A modest inverse correlation was observed between post-operative follow-up duration and conjunctiva-scleral thickness overlying the tube (ρ=-0.44, p=0.034). generalized estimating equation analysis showed a similar association (p=0.019). However, when eyes were categorized according to post-operative follow-up duration (≤1 year, 1-5 years, and ≥5 years), no statistically significant differences in conjunctiva-scleral thickness measurements were detected were observed among the groups: 273 (79-552), 190 (54-402), and 119 (64-227) μm, respectively (p=0.087). CONCLUSION: In this preselected high-risk cohort, a modest inverse correlation was observed between post-operative follow-up duration and conjunctiva-scleral thickness overlying the tube; however, this association was not consistently demonstrated across analytical approaches and should therefore be considered exploratory. Anterior segment optical coherence tomography allows objective characterization of tissue coverage over the Ahmed glaucoma valve tube. Further prospective studies with larger cohorts and appropriate control groups are warranted to determine the clinical significance of these findings.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Optical coherence tomography-guided decision-making for Descemet stripping automated endothelial keratoplasty in Ahmed glaucoma valve-related corneal decompensation.Romanian journal of ophthalmology · 2026
- Topographic and layer-specific mapping of anterior scleral complex thickness using anterior segment OCT: an anatomical reference with potential surgical relevance.International ophthalmology · 2026
- Flanged Intraluminal Suture Occlusion of an Ahmed Glaucoma Valve Tube During Suprachoroidal Hemorrhage Drainage: A Surgical Technique.Retinal cases & brief reports · 2026
- Anterior Scleral Thickness in Young Saudi Adults Measured Using Swept-Source Optical Coherence Tomography: Sex- and Quadrant-Specific Variations.Journal of clinical medicine · 2026
- Correlation between anterior segment optical coherence tomography parameters and visual field results after a single episode of acute angle closure glaucoma.Journal francais d'ophtalmologie · 2026
- Management of Ahmed Glaucoma Valve Plate Exposure by Plate Removal and Tube Retention: A Case Report.International medical case reports journal · 2026