  • This case suggests that removal of an exposed Ahmed glaucoma valve (AGV) plate with retention of the tube may preserve a potential aqueous drainage pathway. However, subsequent conjunctival wound dehiscence and tube exposure required repair with a preserved scleral patch graft, highlighting the importance of adequate tube coverage, particularly in eyes with compromised conjunctiva. Following repair, tube coverage remained intact and intraocular pressure remained stable during eight months of follow-up, although the independent contribution of the retained tube to IOP control could not be confirmed. Longer follow-up and additional cases are needed to establish the efficacy and safety of this individualized approach.

Abstract

BACKGROUND: Ahmed glaucoma valve (AGV) implantation is an established option for refractory glaucoma, including neovascular glaucoma (NVG). Exposure of glaucoma drainage device hardware is a serious complication because it increases the risk of infection and may require surgical repair or explantation. CASE PRESENTATION: A 66-year-old man with diabetes, hypertension, and NVG secondary to diabetic retinopathy developed AGV plate exposure in the right eye two months after implantation. The exposed plate was removed while the tube was retained. The distal open end of the retained tube was positioned subconjunctivally approximately 8 mm posterior to the limbus beneath conjunctival/Tenon tissue. The tube was fixed to the sclera with 10-0 nylon, temporarily ligated with 7-0 Vicryl, and three fenestrations were created proximal to the ligature. Two weeks later, conjunctival wound dehiscence with tube exposure occurred and was repaired with an approximately 4 × 2 mm preserved scleral patch graft. At eight months after the final repair, the eye was quiet, the tube remained covered, and IOP was 14 mmHg while the patient was using dorzolamide-timolol. Tube function was not objectively confirmed. CONCLUSION: This case suggests that removal of an exposed Ahmed glaucoma valve (AGV) plate with retention of the tube may preserve a potential aqueous drainage pathway. However, subsequent conjunctival wound dehiscence and tube exposure required repair with a preserved scleral patch graft, highlighting the importance of adequate tube coverage, particularly in eyes with compromised conjunctiva. Following repair, tube coverage remained intact and intraocular pressure remained stable during eight months of follow-up, although the independent contribution of the retained tube to IOP control could not be confirmed. Longer follow-up and additional cases are needed to establish the efficacy and safety of this individualized approach.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers