To be (IIb), or not to be (IIb) - That is the current status of cuffless blood pressure monitoring device.
Hae-Young Lee, Jeong-Hun Shin, Eun Mi Lee, Sang-Hyun Ihm
Division of Cardiology, Department of Internal Medicine, Seoul National University Hospital, Seoul, Republic of Korea. · Division of Cardiology, Department of Internal Medicine, Hanyang University Guri Hospital, Hanyang University College of Medicine, Guri, Republic of Korea.
Key points
From the paper's conclusion- We analyze the historical landscape of international validation, detail the sequential fulfillment of ESH criteria, and delineate future research imperatives-emphasizing calibration practicality, transient BP changes, and cardiovascular outcome validation-to pave the way for universal clinical adoption.
Abstract
Cuffless blood pressure (BP) monitoring devices have attracted extraordinary scientific and commercial attention, yet their clinical status remains deeply contested. Major international guidelines from the American Heart Association/American College of Cardiology (2025), the European Society of Cardiology (2024), and the European Society of Hypertension (ESH, 2023) uniformly assign a Class III recommendation (not recommended for diagnostic use) to cuffless devices due to insufficient validation and calibration drift. However, the Korean Society of Hypertension has recently updated its guidelines to include cuffless BP monitors as a Class IIb recommendation for out-of-office BP measurement. This review explores the rationale behind this divergence, largely based on the acclumulating validation of a domestic ring-type cuffless device, CART BP (Sky Labs), currently the world's only nationally insured cuffless monitor. We analyze the historical landscape of international validation, detail the sequential fulfillment of ESH criteria, and delineate future research imperatives-emphasizing calibration practicality, transient BP changes, and cardiovascular outcome validation-to pave the way for universal clinical adoption.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Cuffless Devices for the Measurement of Blood Pressure: A Scientific Statement From the American Heart AssociationHypertension · 2025
- Wearable, cuffless, and portable devices for blood pressure monitoring (2015-2025): a scoping review of technologies, calibration, clinical validation, and regulatory frameworks.Frontiers in digital health · 2026
- Wearable devices in the management of hypertension: Navigating the intersection between digital advancement and evidence-based practiceClinical Medicine · 2026
- An Unfinished but Necessary Path: Ring-Based Cuffless Blood Pressure Monitoring at the Crossroads of Innovation and Clinical Reality.Pulse (Basel, Switzerland) · 2026
- Update of the practical guide for validation studies of automated cuff blood pressure monitors according to the Universal Standard by the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization (ISO 81060-2:2018) and Amendments 1:2020 and 2:2024.Journal of hypertension · 2026
- Accuracy of cuffless blood pressure devices compared with invasive arterial line monitoring in high-acuity settings: a random-effects meta-analysisEuropean Heart Journal · 2026