Key points
From the paper's conclusion- The performance of the ActiGraph LEAP is comparable to that of the ActiGraph GT9X Link among healthy young adults, as seen through comparison of aggregated acceleration metrics quantified using the GGIR method.
Abstract
INTRODUCTION: Accelerometers are a common method of direct activity measurement, but the continuous release of newly developed accelerometer device models warrant comparison with previously validated models. The performance of the ActiGraph LEAP, the successor to the widely used ActiGraph GT9X Link, has rarely been compared directly with other accelerometer models. METHODS: Healthy young adults wore both the ActiGraph LEAP and GT9X Link on their non-dominant wrist for seven consecutive days in free-living conditions. An open-source R package (GGIR) was utilized to quantify activity from raw accelerometer data. Raw accelerometer data files were resampled to a common sample rate (30 Hz) and timestamp matched by minute. Aggregated activity metrics, specifically average daily acceleration and peak 30-minute acceleration, were compared through intraclass correlation coefficients (ICC2,1), mean absolute percent error (MAPE), and equivalence tests utilizing ±10% equivalence bounds. Bland-Altman plots visualized agreement. RESULTS: A total of 25 young adults were included (21.2 ± 4.0 years) with an average of 4.1 days of valid wear (≥ 10 hours). Both activity metrics exhibited good to excellent agreement, low MAPE values (<10%), and passed equivalency tests. Additionally, significant proportional bias was not found when analyzing the Bland-Altman plots for each activity metric. CONCLUSIONS: The performance of the ActiGraph LEAP is comparable to that of the ActiGraph GT9X Link among healthy young adults, as seen through comparison of aggregated acceleration metrics quantified using the GGIR method.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Agreement of physical activity metrics from ActivPAL and ActiGraph accelerometers worn concurrently among college students at a residential university.Journal of American college health : J of ACH · 2026
- Absolute Agreement Between a Consumer Wearable and Research Grade Accelerometry in Free-Living Conditions: Comparison Study.JMIR formative research · 2026
- Comparability of accelerometry outcomes across popular metrics and widespread sensor positionsPLoS ONE · 2025
- Identification of Activity Breaks Using Accelerometry.Sensors (Basel, Switzerland) · 2026
- Optimizing accelerometer implementation in a gerotherapeutic trial: Feasibility, adherence, and operational insights of ABLE.PLOS digital health · 2026
- A Head-to-Head Comparison of Three Literature Algorithms for Physical Activity Endpoints from a Wrist Accelerometer in Free-Living Conditions.Sensors (Basel, Switzerland) · 2026