From the paper's conclusion
  • In this work, we leverage a publicly available dataset, CAPTURE-24, including wrist accelerometer data and experts' annotations of various physical activities for 151 healthy adults, monitored at-home for one day, to compare three literature algorithms: Algorithm #1, SciKit Digital Health (SKDH), from Adamowicz et al., Algorithm #2 from Staudenmayer et al., and Algorithm #3 from Montoye et al.

Abstract

Wrist accelerometers are widely used in clinical trials for continuous assessment of participants' day-to-day physical activity and function, through derivation of metrics such as time spent in sedentary, non-sedentary, light, and moderate-to-vigorous physical activity (MVPA). Multiple algorithms have been proposed to derive these physical activity endpoints; however, the agreement across the endpoints derived from these algorithms has not been thoroughly explored. In this work, we leverage a publicly available dataset, CAPTURE-24, including wrist accelerometer data and experts' annotations of various physical activities for 151 healthy adults, monitored at-home for one day, to compare three literature algorithms: Algorithm #1, SciKit Digital Health (SKDH), from Adamowicz et al., Algorithm #2 from Staudenmayer et al., and Algorithm #3 from Montoye et al. Algorithms' outputs were assessed against experts' annotations via paired t-tests, Pearson's correlation (R), Bland-Altman analysis, accuracy, sensitivity, specificity, and F1-score. Algorithm #1 and Algorithm #2 showed stronger correlation and lower bias with experts' annotations for time in sedentary (Algorithm #1: R = 0.91), and MVPA (Algorithm #1: R = 0.63), compared to Algorithm #3. In addition, Algorithm #1 and Algorithm #3 outperformed Algorithm #2 for time in light activity. Future work using longer monitoring periods and reference calorimetry devices should be performed to confirm the reproducibility of these findings.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

A Head-to-Head Comparison of Three Literature Algorithms for Physical Activity Endpoints from a Wrist Accelerometer in Free-Living Conditions — Science Skim