Agreement of physical activity metrics from ActivPAL and ActiGraph accelerometers worn concurrently among college students at a residential university.
Ainsley Harkin, Makayla Cawley, Emma Morrow, Stephanie P Kurti, Trent A Hargens
Human Performance Laboratory, Department of Kinesiology, James Madison University, Harrisonburg, VA, USA.
Key points
From the paper's conclusion- Device agreement varied by metric, emphasizing the importance of measurement selection in college student research. Reliable step-based measurement may support research needed to develop step recommendations and physical activity promotion strategies for college students.
Abstract
OBJECTIVE: To examine agreement between concurrently worn ActivPAL (AP) and ActiGraph (AG) accelerometers in college students. METHODS: Thirty-six students (age 21.6 ± 2.4 years) wore AP and AG accelerometers for 4-8 days. Agreement was assessed using paired t-tests, intraclass correlation coefficients, mean absolute percentage error, Bland-Altman analyses, and ±10% equivalence testing. RESULTS: AG wear time averaged 15.5 ± 1.0 h/day. Compared with AP, AG measured 698 ± 805 fewer steps/day, 69 ± 70 more sedentary min/day, and 112 ± 57 fewer zero cadence min/day. Peak 1-min and 30-min cadence demonstrated strong agreement and met equivalence criteria. Daily steps showed agreement but did not meet equivalence; sedentary and zero cadence time demonstrated the weakest agreement. CONCLUSIONS: Device agreement varied by metric, emphasizing the importance of measurement selection in college student research. Reliable step-based measurement may support research needed to develop step recommendations and physical activity promotion strategies for college students.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Absolute Agreement Between a Consumer Wearable and Research Grade Accelerometry in Free-Living Conditions: Comparison Study.JMIR formative research · 2026
- Activity Metrics from the ActiGraph GT9X Link and ActiGraph LEAP Using an Open-Source R Package.Research in health and medicine · 2026
- A Head-to-Head Comparison of Three Literature Algorithms for Physical Activity Endpoints from a Wrist Accelerometer in Free-Living Conditions.Sensors (Basel, Switzerland) · 2026
- Comparability of accelerometry outcomes across popular metrics and widespread sensor positionsPLoS ONE · 2025
- Comparing the reliability of sleep metrics across two wrist actigraphs: Philips Actiwatch Spectrum Plus and ActiGraph CentrePoint Insight watchSleep Science and Practice · 2026
- Análisis de los patrones de movimiento de 24 horas en estudiantes universitariosJUMP · 2026