Temporary stent-post cinching to facilitate minimally invasive implantation of the Avalus aortic bioprosthesis.
Digvijay Ar, Hari Govind Varma, Rakesh Gayen, Sudipto Sinha, Lalit Kapoor
NH Rabindranath Tagore International Institute of Cardiac Sciences, Kolkata, India.
Key points
From the paper's conclusion- We feel that this should be at the disposal of every surgeon, and we suggest that it may facilitate safe implantation of the Avalus valve in minimally invasive cardiac surgery.
Abstract
Bioprosthetic valves are often supplied with a cinching mechanism in the box. This is to prevent leaflet damage during valve implantation. The incidence of valve damage during implantation is further higher in minimally invasive cardiac surgery. The implantation of a valve in both aortic and mitral positions in minimally invasive surgeries is often challenging due to both the anatomy and the poor visualisation of both the valve and the surrounding structures during implantation which can lead to potential complications of structural damage to the valve leaflets. Various commercially available valves have a work around this issue by positioning the holder with respect to the valve to prevent the dreaded complications that occur during implantation. The Avalus valve is not supplied in the box with a cinching mechanism. This poses a challenge to safe implantation of the valve. During implantation of the valve, due to the relative orientation of the holder to the valve leaflets, there is potential for leaflet damage and tear due to suture entanglement. This complication occurring during implantation can be prevented by using the surgical technique described in this report. Our experience with this technique has been satisfactory. We feel that this should be at the disposal of every surgeon, and we suggest that it may facilitate safe implantation of the Avalus valve in minimally invasive cardiac surgery.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Feasibility, Technical Safety, and Early Clinical Experience with an Automated Annular Suturing Device in Minimally Invasive Valve Replacement.Journal of clinical medicine · 2026
- Association of Implantation Depth With Hemodynamics and Mechanical Consequences in Small Valve-In-Valve TAVR.JACC. Asia · 2026
- Sutureless Aortic Valve Replacement as a Bailout Strategy for Type A Aortic Dissection: 2 Case Reports.Journal of chest surgery · 2026
- A biomimetic, bioengineered polymeric pulmonary valve promotes native tissue remodeling and thrombosis-free function in a chronic ovine modelEuropean Heart Journal · 2026
- Case Example and Bench Testing of Hydrodynamic Performance and Migration Stability of Various Valve-in-Valve Configurations within a Large-Housing Self-Expanding Pulmonary Valve.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026
- First-in-Human Mechanical Bilateral Iatrogenic Coronary Leaflet Obstruction Risk Nullification (BICORN) for Transcatheter Aortic Valve-in-Valve Replacement.JACC. Case reports · 2026