JACC. Case reports

First-in-Human Mechanical Bilateral Iatrogenic Coronary Leaflet Obstruction Risk Nullification (BICORN) for Transcatheter Aortic Valve-in-Valve Replacement.

Hussam Al Hennawi, Vernon Mascarenhas, Abdellaziz Dahou, Ahmad Sameed Akram, Tariq Ahmad

Department of Cardiology, Geisinger College of Health Sciences, Wilkes-Barre, Pennsylvania, USA; Richard and Marion Pearsall Heart Hospital, Geisinger Health System, Wilkes-Barre, Pennsylvania, USA. · Department of Internal Medicine, Geisinger College of Health Sciences, Wilkes-Barre, Pennsylvania, USA.

Trial

Key points

From the paper's conclusion
  • Mechanical traversal may facilitate BICORN when cardiac rotation, unfavorable catheter trajectory, neosinus malalignment, eccentric coronary takeoffs, or leaflet fibrocalcification make electrosurgical traversal challenging.

Abstract

OBJECTIVES: We describe mechanical leaflet traversal as an alternative to electrosurgical traversal for BICORN during valve-in-valve transcatheter aortic valve replacement in a patient with unfavorable cardiac orientation and extreme bilateral coronary obstruction risk. KEY STEPS: The ShortCut device created targeted basal splits in both coronary leaflets. The left coronary cusp split was crossed using a Pilot 100 guidewire (Abbott) and microcatheter with an EBU 3.5 guide catheter (Medtronic) and Agilis steerable introducer (Abbott) support. After balloon dilation, the left coronary cusp was translocated with an 18-mm True Dilatation Balloon (BD). A 20-mm SAPIEN 3 Ultra transcatheter heart valve (Edwards Lifesciences) was then advanced through the right coronary cusp split and deployed within the pre-existing 23-mm SAPIEN 3 valve (Edwards Lifesciences). POTENTIAL PITFALLS: Mechanical traversal requires precise targeting. Leaflet translocation may cause embolization, severe aortic insufficiency, or hemodynamic compromise, requiring readiness for immediate valve deployment. TAKE-HOME MESSAGE: Mechanical traversal may facilitate BICORN when cardiac rotation, unfavorable catheter trajectory, neosinus malalignment, eccentric coronary takeoffs, or leaflet fibrocalcification make electrosurgical traversal challenging.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers