Biomechanical stability and monitoring technologies of implant-supported prosthetic components.
Jefferson David Melo de Matos, Mário Alexandre Coelho Sinhoreti, Mauricio Schneider, Robert Dobrin, Daher Antonio Queiroz
Department of Biomaterials, Dental Materials and Prosthodontics, São Paulo State University (Unesp), Institute of Science and Technology, São José dos Campos, Sao Paulo, B. · Department of Restorative Dentistry, Dental Materials Division, Piracicaba Dental School (FOP UNICAMP), Piracicaba, Sao Paulo, Brazil.
Key points
From the paper's conclusion- Mechanical stability in implant-supported rehabilitations is strongly associated with preload preservation and implant-abutment integrity. Advanced monitoring technologies show promising potential for improving the early diagnosis of biomechanical instability; however, further prospective clinical studies are required before routine clinical implementation can be recommended.
Abstract
BACKGROUND: Mechanical stability is a critical factor for the long-term success of implant-supported rehabilitations. The maintenance of preload within the implant-abutment complex plays a fundamental role in preventing prosthetic complications, particularly screw loosening and loss of joint stability. Advances in monitoring technologies, including ultrasonic methods, piezoelectric sensors, and electromechanical impedance techniques, have introduced new possibilities for the early detection of biomechanical alterations in implant-supported prosthetic components. MATERIALS AND METHODS: A structured narrative review was performed through comprehensive literature searches in PubMed/MEDLINE, Scopus, Web of Science and SciELO databases. The retrieved literature was critically analyzed according to biomechanical principles, preload maintenance, screw loosening mechanisms and emerging monitoring technologies. RESULTS: The reviewed studies demonstrated that preload maintenance is essential for the biomechanical stability and longevity of implant-supported rehabilitations. Prosthetic screw loosening was identified as a prevalent mechanical complication, especially under cyclic and non-axial loading conditions. Internal conical and Morse taper connections generally showed improved preload maintenance compared with external hexagon systems. Additionally, ultrasonic monitoring, piezoelectric sensors, and electromechanical impedance methods demonstrated potential for early detection of preload loss and biomechanical instability. Although promising, most monitoring technologies remain limited to experimental investigations. CONCLUSIONS: Mechanical stability in implant-supported rehabilitations is strongly associated with preload preservation and implant-abutment integrity. Advanced monitoring technologies show promising potential for improving the early diagnosis of biomechanical instability; however, further prospective clinical studies are required before routine clinical implementation can be recommended.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Titanium Base-Free Multi-Unit Abutment Connections: A Critical Review of Prosthetic Screw Design, Biomechanical Behavior, and Clinical PerformanceMaterials · 2026
- Influence of different abutment materials on torque maintenance and screw loosening in implant-supported prostheses.Bioinformation · 2026
- The impact of abutment manufacturing techniques on reverse torque after cyclic loading and implant-abutment interface fitting: an in vitro study.BMC oral health · 2026
- Marginal Bone Loss and Peri-Implant Clinical Outcomes of Internal Hexagonal and Internal Conical Implant Abutment Connections: A Narrative Review.Cureus · 2026
- Interaction Between Implant Macrogeometry and Osteotomy Preparation on Immediate Mechanical Fixation and Regional Thread Alterations: An Ex Vivo Biomechanical Study.Bioengineering (Basel, Switzerland) · 2026
- A comparative analysis of efficacy of torque limiting devices provided by different dental implant manufacturersBMC Oral Health · 2026