Interaction Between Implant Macrogeometry and Osteotomy Preparation on Immediate Mechanical Fixation and Regional Thread Alterations: An Ex Vivo Biomechanical Study.
Almudena Banegas-Cano, Arturo Sánchez-Pérez, Alfonso Jornet-García, José María Montoya-Carralero, María José Moya-Villaescusa
Periodontology Unit, Faculty of Medicine, University of Murcia, 30008 Murcia, Spain.
Key points
From the paper's conclusion- Under these experimental conditions, implant macrogeometry and osteotomy preparation acted as interdependent determinants of immediate mechanical behavior and were associated with distinct regional patterns of post-removal, visually detectable thread alterations.
Abstract
Immediate implant mechanics may depend on the interaction between implant macrogeometry and osteotomy preparation, but their combined influence on complementary measures of immediate fixation and regional thread alterations remains insufficiently characterized. This ex vivo study evaluated two implant macrogeometries and four osteotomy techniques in 80 bovine rib specimens (n = 10 per group). Reverse torque resistance remained the primary mechanical outcome; prospectively recorded insertion torque and resonance frequency analysis (implant stability quotient [ISQ]) were incorporated in the revision as complementary immediate mechanical outcomes. Thread alterations were assessed qualitatively after removal in the cervical, body, and apical regions. Insertion torque was significantly influenced by macrogeometry and preparation technique, without a significant interaction. Reverse torque resistance showed significant effects of macrogeometry, preparation technique, and their interaction (all p < 0.001). ISQ showed a significant macrogeometry-by-technique interaction. Insertion torque correlated strongly with reverse torque resistance (r = 0.645, p < 0.001), whereas ISQ showed a more moderate association (r = 0.370, p < 0.001), supporting related but non-interchangeable mechanical constructs. Cervical alterations were mainly associated with undersized drilling, whereas apical alterations occurred predominantly in the Quattro design; none were observed in the implant body. External surface temperature showed no overall change or consistent technique-dependent increase. Under these experimental conditions, implant macrogeometry and osteotomy preparation acted as interdependent determinants of immediate mechanical behavior and were associated with distinct regional patterns of post-removal, visually detectable thread alterations.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effects of osteotomy preparation protocols and implant macrogeometry on primary stability in an ex vivo bovine-rib modelBMC Oral Health · 2026
- Effect of Progressive Versus Standard Implant Thread Designs on Primary Stability and Insertion Torque: An In Vitro StudyThe International Journal of Oral & Maxillofacial Implants · 2026
- Influence of Implant Macrodesign on Primary Stability Across Different Bone Density Models: A Comparative In Vitro Study.Journal of functional biomaterials · 2026
- Influence of Reduced Cortical Bone Compression by Implant Macrogeometry on Peri-Implant Bone Healing: An In Vitro and In Vivo Experimental StudyJournal of Functional Biomaterials · 2026
- Influence of Implant Macrogeometry on Primary Stability in Different Polyurethane Bone-Density Models: An In Vitro Study.Bioengineering (Basel, Switzerland) · 2026
- Primary Stability of Implants Inserted Using Different Osseodensification Systems in Low-Density Bone: An In Vitro StudyDentistry Journal · 2026