Additive Value of Whole-body CT in Patients Imaged with PET/CT for Solitary Pulmonary Nodules.
Elif Şahin Kütük, Ümit Özgür Akdemir, Mustafa Ünlü
Ankara Bilkent City Hospital, Clinic of Nuclear Medicine, Ankara, Türkiye. · Gazi University Faculty of Medicine, Department of Nuclear Medicine, Ankara, Türkiye.
Key points
From the paper's conclusion- In SPN PET/CT evaluation, routine body CT does does not provide clinically significant additional information in most patients but substantially increases radiation exposure. Performing thoracic CT following whole-body PET, with additional targeted CT only when extrathoracic PET abnormalities are detected, may reduce radiation exposure while preserving the diagnostic information provided by CT of the thorax. However, such an approach prolongs acquisition time and increases workload.
Abstract
OBJECTIVES: In routine positron emission tomography/computed tomography (PET/CT) imaging of solitary pulmonary nodules (SPNs), CT acquisition is typically performed from the vertex to the mid-thigh. The administered 18F-fluorodeoxyglucose (18F-FDG) dose is adjusted according to patient weight and is independent of the scanned body region; however, radiation exposure from the CT component increases with scan length. In this study, we aimed to evaluate the clinical value of extrathoracic CT imaging in patients undergoing PET/CT for SPN characterization and to quantify the potential reduction in radiation dose when CT is limited to the thorax. METHODS: A total of 154 patients who underwent 18F-FDG PET/CT for the evaluation of SPNs between 2009 and 2011 were retrospectively analyzed. None of the patients had a prior diagnosis of malignancy or had received chemotherapy or radiotherapy. Incidental extrathoracic CT findings were classified as major, moderate, or minor according to their clinical significance. CT radiation dose was estimated using dose-length product (DLP) values. PET findings, incidental CT findings, radiation dose, and acquisition times were evaluated. RESULTS: Extrathoracic CT findings were detected in 61 patients (39%), with a total of 86 incidental lesions. However, only 3 patients (2%) had major extrathoracic findings requiring urgent clinical intervention. Two of these were osteolytic bone lesions that were 18F-FDG avid and potantially detectable on whole-body PET. Extrathoracic 18F-FDG uptake was observed in 10 patients (6.5%). The mean DLP was 458.3±70.5 mGy cm for whole-body CT and 130.8±9.1 mGy cm for thorax-only CT, corresponding to a 3.5-fold higher CT radiation dose (p<0.01). A PET-based protocol, however, prolongs acquisition time by approximately 6 minutes. CONCLUSION: In SPN PET/CT evaluation, routine body CT does does not provide clinically significant additional information in most patients but substantially increases radiation exposure. Performing thoracic CT following whole-body PET, with additional targeted CT only when extrathoracic PET abnormalities are detected, may reduce radiation exposure while preserving the diagnostic information provided by CT of the thorax. However, such an approach prolongs acquisition time and increases workload.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Optimization of patient dose and image quality for positron emission tomography-computed tomography.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026
- Whole-Body CT Utilisation in Adult Trauma: Guideline Compliance, Incidental Findings, and the Role of Anticoagulation in Low-Energy Falls at a Regional New Zealand Centre.Journal of medical imaging and radiation oncology · 2026
- Effect of Personalized Approach to CT Scan Length on Radiation Dose in Parathyroid SPECT/CT.Journal of nuclear medicine technology · 2026
- Comparison of Diagnostic Performance of Whole-Body 360° CZT Bone SPECT/CT and Planar Bone Scintigraphy in Detecting Bone Metastasis in Small Cell Lung Cancer.Diagnostics (Basel, Switzerland) · 2026
- Estimation of the effective dose in torso 18F-fluorodeoxyglucose PET/CT: an analysis of real-world clinical data from 51,784 patient scansEJNMMI Physics · 2026
- Pulmonary Iodine Map Defects Across Contrast Phases in Routine Photon-Counting Detector CT: An Exploratory Study.Diagnostics (Basel, Switzerland) · 2026