Pulmonary Iodine Map Defects Across Contrast Phases in Routine Photon-Counting Detector CT: An Exploratory Study.
Momo Wakui, Kota Yokoyama, Hirofumi Yamada, Yusuke Kawasaki, Hiroto Hada, Junichi Tsuchiya, Akihiro Hirakawa, Ukihide Tateishi
Department of Diagnostic Radiology and Nuclear Medicine, Institute of Science Tokyo, Tokyo 113-8510, Japan. · Department of Clinical Biostatistics, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo, Tokyo 113-8510, Japan.
Key points
From the paper's conclusion- Overall, PE was identified in 6/442 examinations (1.4%), including three findings absent from the original reports.
Abstract
Background/Objectives: Pulmonary iodine maps are routinely available from photon-counting detector computed tomography (PCD-CT), including examinations not optimized for pulmonary embolism (PE) assessment. We evaluated the frequency and contrast-phase distribution of pulmonary iodine map defects in routine clinical practice. Methods: This retrospective single-center study included 442 contrast-enhanced PCD-CT examinations in 433 patients during March-April 2026, each with whole-lung coverage in at least one postcontrast phase. Examinations were classified as dedicated pulmonary arterial, other whole-lung arterial, or nonarterial-only imaging. Two radiologists independently reviewed iodine maps followed by 70-keV virtual monoenergetic images, with disagreements resolved by consensus. Analyses were descriptive; no independent reference standard was available. Results: Iodine map defects were identified in 4/442 examinations (0.9%; 95% confidence interval, 0.2-2.3%), all corresponding to pulmonary arterial filling defects interpreted as PE. Defects occurred in 2/15 dedicated pulmonary arterial examinations and 2/70 other arterial examinations, versus 0/357 nonarterial-only examinations. In all three iodine-defect-positive examinations with paired later-phase imaging, iodine defects were no longer visible. Overall, PE was identified in 6/442 examinations (1.4%), including three findings absent from the original reports. Interobserver agreement was κ = 0.86 for iodine defects and κ = 0.83 for PE. Conclusions: Arterial-phase iodine maps may provide clues to PE on routine PCD-CT, even when acquisition is not timed to the pulmonary arterial phase. Absence of iodine defects on nonarterial images should not be used to exclude PE. Larger studies are needed to establish diagnostic benefit.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Reducing contrast media dosage for pulmonary embolism CTPA in PCD-CT: a comparative study of EID-CT and PCD-CT in the era of individualized protocollingEuropean Radiology · 2025
- Pulmonary nodule image quality and morphologic visualization with photon-counting detector CT: a scoping reviewEuropean Radiology Cardiovascular and Thoracic · 2026
- Pulmonary Artery CT Angiography on Photon-Counting Detector CT: A Practical One-Stop Acquisition, Reconstruction, and Reporting Protocol.Tomography (Ann Arbor, Mich.) · 2026
- Improvement of Lung Nodule Volumetric Accuracy with Photon-counting Computed Tomography Over Energy-integrating Computed Tomography in Low-dose ScreeningInvestigative Radiology · 2026
- Photon-counting CT angiography in a multi-trauma patient with bilateral pulmonary embolism: combined vascular mapping and quantitative iodine-density assessment prior to scalp reconstruction: case report.Frontiers in medicine · 2026
- Photon-counting detector CT for CT pulmonary angiography: a systematic review and meta-analysis.European radiology · 2026