Comparison of Diagnostic Performance of Whole-Body 360° CZT Bone SPECT/CT and Planar Bone Scintigraphy in Detecting Bone Metastasis in Small Cell Lung Cancer.
Sang Mi Lee, Su Jin Jang, Ju Ock Na, Ki Hyun Seo, Nam Hun Heo, Jeong Won Lee
Department of Nuclear Medicine, Soonchunhyang University Cheonan Hospital, 31 Suncheonhyang 6-gil, Dongnam-gu, Cheonan 31151, Republic of Korea. · Department of Nuclear Medicine, CHA Bundang Medical Center, CHA University School of Medicine, 59 Yatap-ro, Bundang-gu, Seongnam 13496, Republic of Korea.
Key points
From the paper's conclusion- Background/Objectives: We aimed to compare the diagnostic performances of planar bone scintigraphy and whole-body 360° cadmium-zinc-telluride (CZT) bone single-photon emission computed tomography/computed tomography (SPECT/CT) in detecting bone metastasis in patients with small cell lung cancer (SCLC).
Abstract
Background/Objectives: We aimed to compare the diagnostic performances of planar bone scintigraphy and whole-body 360° cadmium-zinc-telluride (CZT) bone single-photon emission computed tomography/computed tomography (SPECT/CT) in detecting bone metastasis in patients with small cell lung cancer (SCLC). Methods: We retrospectively evaluated two separate, non-randomized cohorts of 175 patients with SCLC who underwent staging bone scintigraphy, comprising 93 and 82 patients who underwent planar bone scintigraphy using a conventional dual-head gamma camera and whole-body bone SPECT/CT using a full-ring 360° CZT camera, respectively. Both imaging examinations were visually assessed and compared using patient- and lesion-based analyses of their diagnostic performances. Results: Whole-body bone SPECT/CT showed fewer equivocal findings and almost perfect inter-reader agreement. On the patient-based analysis, whole-body bone SPECT/CT demonstrated higher unadjusted observed diagnostic accuracy than planar bone scintigraphy (87.8% vs. 73.1%; p = 0.016), with higher observed sensitivity (79.2% vs. 53.3%), specificity (91.4% vs. 82.5%), positive predictive value (79.2% vs. 59.3%) and negative predictive value (91.4% vs. 78.8%). However, on a lesion-based analysis, whole-body bone SPECT/CT exhibited a low sensitivity of 47.5%, with particularly low detection rates for spine and pelvic metastases (29.4%), despite showing higher observed sensitivity than planar bone scintigraphy (20.1%). Conclusions: In two separate retrospective cohorts of SCLC patients, whole-body bone SPECT/CT showed higher unadjusted observed patients-based diagnostic performance than planar bone scintigraphy. However, its lesion-level sensitivity remained low, particularly in the spine and pelvis.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Development and Initial Validation of a Statistical Image Analysis Framework for Quantitative Bone SPECT/CT in Patients with Prostate Cancer.Diagnostics (Basel, Switzerland) · 2026
- Photon-counting detector CT in oncology: a new era of cancer imagingInsights into Imaging · 2026
- Systematic evaluation of energy window and reconstruction parameters for quantitative lutetium‐177 SPECT imaging on a CZT‐based starguide SPECT/CT systemJournal of Applied Clinical Medical Physics · 2026
- Diagnostic Performance of CT Bone-RADS in a Cohort of CT-Guided Bone BiopsiesDiagnostics · 2026
- Image quality and dose performance of photon-counting CT in multiple myeloma: a comparative clinical study.Journal of cancer research and clinical oncology · 2026
- Local Diagnostic Reference Levels for Adult Bone SPECT/CT Imaging: A Multicenter Study in South AfricaWorld Journal of Nuclear Medicine · 2026