Incidence, predictors, and clinical impact of hypoattenuating leaflet thickening following SAPIEN 3 Ultra RESILIA implantation
Kenichi Ishizu, Shinichi Shirai, Masaomi Hayashi, Toru Morofuji, Akihiro Isotani, Nobuhisa Ohno, Shinichi Kakumoto, Kenji Ando,
Kokura Memorial Hospital · Toyohashi Heart Center
Key points
From the paper's conclusion- Our study aimed to elucidate the clinical features of HALT following S3UR implantation.
Abstract
BACKGROUND: The latest-generation SAPIEN 3 Ultra RESILIA (S3UR) transcatheter heart valve (THV) incorporates several changes in leaflet design, including an improved anticalcification coating and modified commissural attachment. There are no established data on hypoattenuating leaflet thickening (HALT) following transcatheter aortic valve implantation (TAVI) using the S3UR. AIMS: Our study aimed to elucidate the clinical features of HALT following S3UR implantation. METHODS: As a subset of the OCEAN (Optimized CathEter vAlvular INtervention)-TAVI registry, we prospectively assessed patients who underwent cardiac computed tomography (CT) 30 days after S3UR implantation. HALT and potentially relevant THV geometry were analysed using four-dimensional CT data by an independent core laboratory. RESULTS: Of the 445 patients studied, HALT was detected in 95 patients (21.3%) 30 days after TAVI. The modification of the commissural attachment specific to the 20 mm and 23 mm S3UR THVs did not affect the incidence of HALT (22.1% for ≤23 mm; 20.2% for ≥26 mm; p=0.636). The hourglass-shaped THV frame (p<0.001) and asymmetricity of THV leaflets (p=0.002) were independently associated with HALT development. A trend toward higher mean aortic gradients at 30 days with greater degrees of HALT (HALT >25% vs HALT ≤25%: 10.3 [interquartile range [IQR] 7.0-13.0] mmHg vs 8.6 [IQR 6.3-11.6] mmHg; p=0.007; HALT >50% vs HALT ≤50%: 11.5 [IQR 7.0-14.3] mmHg vs 8.9 [IQR 6.3-11.9] mmHg; p=0.002) was noted. CONCLUSIONS: The incidence of HALT for the S3UR was comparable with the already reported incidences for the previous-generation SAPIEN 3 THV. Given the haemodynamic impact of HALT severity and multiplicity, strategic planning to avoid deformation of the implanted THV might be required. (Clinical trial registration: UMIN000020423).
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Association between HALT incidence and deformation of transcatheter aortic valve prostheses: Sapien vs. Evolut vs. NavitorEuropean Heart Journal · 2026
- Early hemodynamic impact of hypoattenuated leaflet thickening in new-generation transcatheter heart valvesEuropean Heart Journal · 2026
- Case Report: Serial 4D-CT evolution from focal leaflet thickening to multileaflet HALT after transcatheter aortic valve replacement in a hemodialysis patient.Frontiers in cardiovascular medicine · 2026
- Hypo-attenuated leaflet thickening after surgical aortic valve replacement with INSPIRIS RESILIA valve.General thoracic and cardiovascular surgery · 2026
- Clinical significance of CT-detected hypoattenuated leaflet thickening after transcatheter aortic valve replacement: A systematic review and meta-analysis.Journal of cardiovascular computed tomography · 2026
- Optimized Balloon-Expandable Transcatheter Aortic Valve Implantation and Clinical Outcomes.JACC. Advances · 2026