Early hemodynamic impact of hypoattenuated leaflet thickening in new-generation transcatheter heart valves
K Hattori, K Matsushita, K Terasaka, T Yoshii, S Kikuchi, K Tsutsumi, H Kirigaya, H Nakahashi,
Key points
From the paper's conclusion- Background/Introduction The incidence and hemodynamic impact of hypoattenuated leaflet thickening (HALT) in new-generation transcatheter heart valves (THVs) have not been fully elucidated.
Abstract
Background/Introduction The incidence and hemodynamic impact of hypoattenuated leaflet thickening (HALT) in new-generation transcatheter heart valves (THVs) have not been fully elucidated. Purposes The purpose of this study is to investigate the hemodynamic impact of HALT. Methods We enrolled 306 cases of transcatheter aortic valve implantation (TAVI) performed between July 2023 and October 2025. Balloon-expandable valves (BEVs) included Sapien3 Ultra RESILIA, while self-expanding valves (SEVs) included Evolut FX, Evolut FX+, and Navitor. A total of 212 patients with both one-month follow-up computed tomography and echocardiography were analyzed. Results BEV and SEV were implanted in 106 patients each. The incidence of HALT was significantly lower in the BEV group compared with the SEV group (21% vs. 36%, p=0.01). In the SEV group, the presence of HALT did not significantly affect the mean transprosthetic pressure gradient (PG) (8.5 mmHg vs. 8.8 mmHg, p=0.65). In contrast, HALT was associated with a significantly higher mean PG in the BEV group (12.5 mmHg vs. 9.8 mmHg, p=0.02). Notably, this effect was evident only in patients receiving 20mm (25.7 mmHg vs. 14.8 mmHg, p=0.053) and 23mm BEVs (11.9 mmHg vs. 9.8mmHg, p=0.044). Conclusion Among new-generation THVs, HALT was less frequent in BEVs compared with SEVs. However, HALT at one month after TAVI was associated with an increased mean PG in BEVs, particularly in smaller THVs.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Association between HALT incidence and deformation of transcatheter aortic valve prostheses: Sapien vs. Evolut vs. NavitorEuropean Heart Journal · 2026
- Early Post-transcatheter Aortic Valve Implantation (TAVI) Haemodynamics With SAPIEN Balloon-Expandable and Evolut Self-Expanding Valve Platforms: A Retrospective Single-Centre Cohort Study.Cureus · 2026
- Incidence, predictors, and clinical impact of hypoattenuating leaflet thickening following SAPIEN 3 Ultra RESILIA implantationEuroIntervention · 2025
- Impact of self-expanding valve selection on hemodynamics and clinical outcomes in patients with borderline annular dimensions for balloon-expandable valve: insights from the multicenter-TAVI registryEuropean Heart Journal · 2026
- Clinical significance of CT-detected hypoattenuated leaflet thickening after transcatheter aortic valve replacement: A systematic review and meta-analysis.Journal of cardiovascular computed tomography · 2026
- Balloon-Expandable Vs Self-Expanding Valves for Transcatheter Aortic Valve Implantation in Internally Stented Surgical Valves.CJC open · 2026