Testicular Volume Measurement: Comparison of Prader Orchidometer, Calliper and Ultrasound Estimates with Actual Volume Obtained by Water Displacement.
Olufemi O Ojewuyi, Emmanuel A Jeje, Amogu Kalu Eziyi, Abimbola A Abolarinwa, Abiodun Ronke Ojewuyi
Department of Surgery, Osun State University, UNIOSUN Teaching Hospital, Osogbo, Nigeria. · Department of Surgery, University of Lagos, Lagos University Teaching Hospital, Idi-araba, Nigeria.
Key points
From the paper's conclusion- Prader orchidometer provides an accurate and rapid assessment of testicular volume; it is, therefore, useful in clinical practice. Calliper does not give an accurate assessment of testicular volume. Of the three ultrasound formulae, Lambert formula is the best in providing a near accurate testicular volume measurement.
Abstract
INTRODUCTION: The volume of the testis, mainly made up of seminiferous tubules, is a reflection of spermatogenesis. The accurate measurement of the testicular volume is therefore critical in the evaluation of testicular function. Aim is to compare the volumes obtained by Prader orchidometer, calliper and ultrasound with actual volume in humans. MATERIALS AND METHODS: One hundred testicles from 50 men with advanced prostate cancer were recruited into the study over a 12-month period. Testicular volume was estimated in vivo using Prader orchidometer, calliper, ultrasound scan and in vitro after orchidectomy by water displacement. STATISTICAL ANALYSIS USED: Statistical analysis used paired t test, Pearson correlation coefficient and simple linear regression analysis. RESULTS: The age of the patients ranged from 55 to 82 years (mean 71.66 ± 6.5). The mean testicular volumes were 16.13 ± 4.5, 9.07 ± 3.5 and 13.48 ± 4.3mL for Prader orchidometer, calliper and ultrasound (Lambert formula), respectively. The mean volume from water displacement was 15.08 ± 4.3 mL. The Prader orchidometer most appropriately estimates the actual volume, (P = 0.657). Calliper significantly underestimated the actual volume. Ultrasound estimation by Lambert formula showed no significant mean difference from the actual volume (P = 0.362). In addition, the orchidometer and Lambert ultrasound formula showed excellent positive correlation with the actual volume (r = 0.931, P < 0.001) and (r = 0.869, P < 0.001), respectively. CONCLUSIONS: Prader orchidometer provides an accurate and rapid assessment of testicular volume; it is, therefore, useful in clinical practice. Calliper does not give an accurate assessment of testicular volume. Of the three ultrasound formulae, Lambert formula is the best in providing a near accurate testicular volume measurement.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- MRI-derived prostate volume assessment: manual segmentation versus two-axis ellipsoid approximation and its implications for PSA density.European radiology · 2026
- Tomographic ultrasound (tUS) for thyroid volume determination.The ultrasound journal · 2026
- Prostate volume on transrectal ultrasound: comparing ultrasounds performed by urologists to radiologists.The Canadian journal of urology · 2026
- In-Life Testicular Volume as an Indicator of Histological Testicular Development Suitable for Testicular Toxicity Evaluation in Male Cynomolgus Macaques (Macaca fascicularis).Animals : an open access journal from MDPI · 2026
- Multimodal Ultrasonography Predicts Sperm Retrieval Success in Nonobstructive Azoospermia: A Retrospective Diagnostic Study.Ultrasound in medicine & biology · 2026
- Is the density of transition zone prostate tissue truly 1 gram per milliliter?-an evaluation of HoLEP specimens.Translational andrology and urology · 2026