Tomographic ultrasound (tUS) for thyroid volume determination.
Michael Pöhlmann, Martin Freesmeyer, Christian Kühnel, Falk Gühne, Philipp Seifert
Clinic of Nuclear Medicine, University Hospital Jena, Jena, Germany.
Key points
From the paper's conclusion- In this feasibility study, physician-corrected tUS reduced the size-dependent systematic underestimation observed with 2D ultrasound and yielded volumes closer to ceCT, particularly in enlarged glands, within a clinically feasible workflow. Because the best-performing method required manual expert correction and the limits of agreement with ceCT exceeded the predefined clinical threshold, corrected tUS should be regarded as a promising semi-automated approach that requires further validation, including interobserver assessment, before it can be considered interchangeable with ceCT.
Abstract
BACKGROUND: Accurate thyroid volume determination is essential for treatment planning. This feasibility study evaluated the accuracy of a novel tomographic ultrasound (tUS) approach compared to 2D ultrasound, using contrast-enhanced computed tomography (ceCT) as reference standard. METHODS: In this prospective, single-center study, 50 patients undergoing neck ceCT were enrolled. Thyroid volume was measured by 2D ultrasound (ellipsoid model), automatedvolume (tUS uncorrected), physician-corrected volume (tUS corrected) and ceCT. Linear regression for proportional bias, log-transformed Bland-Altman analysis, clinical error metrics and correction duration were evaluated. RESULTS: 2D ultrasound showed significant proportional bias (slope=-0.215, p<0.0001) and systematic underestimation (mean difference -6.0mL; geometric mean ratio 0.76). Corrected tUS eliminated proportional bias (p=0.0557) and reduced bias (mean difference +0.8mL; geometric mean ratio 1.04). Corrected tUS achieved lower MAE (4.42mL vs. 6.53mL) and MAPE (19.4% vs. 25.4%) than 2D ultrasound, placing 60.0% vs. 34.0% of cases within ±20% error limits. In enlarged glands (n=19), corrected tUS maintained superior accuracy (MAE 5.82mL, MAPE 12.4%) versus 2D ultrasound (MAE 11.35mL, MAPE 26.5%). Physician correction averaged 2:51minutes, independent of thyroid volume (r=-0.081, p=0.5784). CONCLUSIONS: In this feasibility study, physician-corrected tUS reduced the size-dependent systematic underestimation observed with 2D ultrasound and yielded volumes closer to ceCT, particularly in enlarged glands, within a clinically feasible workflow. Because the best-performing method required manual expert correction and the limits of agreement with ceCT exceeded the predefined clinical threshold, corrected tUS should be regarded as a promising semi-automated approach that requires further validation, including interobserver assessment, before it can be considered interchangeable with ceCT.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Tomographic 3D Ultrasound for Thyroid Volumetry-A Comparison Between Multiplanar 2D and 3D Imaging Methods.Diagnostics (Basel, Switzerland) · 2026
- ACR TI-RADS Modified by CEUS Features and Nodule Location for Diagnosis and Biopsy Decision in Thyroid Nodules of TR4 or Higher.Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine · 2026
- A scoring model using conventional ultrasound and contrast-enhanced ultrasound to identify benign ACR TI-RADS 4 and 5 thyroid nodules: A retrospective clinical study.Clinical imaging · 2026
- Testicular Volume Measurement: Comparison of Prader Orchidometer, Calliper and Ultrasound Estimates with Actual Volume Obtained by Water Displacement.Journal of the West African College of Surgeons · 2026
- Could superb microvascular imaging or shear wave elastography tell us the growth record of suspicious thyroid nodules measuring ≤ 10 mm? A retrospective study.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2026
- Diagnostic Performance of ACR TI-RADS, EU-TI-RADS, and Individual Ultrasound Features for Predicting Thyroid Malignancy: A Histopathology-Validated Analysis of Surgically Excised Nodules.Cureus · 2026