MRI-derived prostate volume assessment: manual segmentation versus two-axis ellipsoid approximation and its implications for PSA density.
Larissa Gluesing, Sophie Potts, Lars Knieper, Francesco Giganti, Igor Tsaur, Sebastian Gassenmaier, Josephine Berger, Konstantin Nikolaou,
Department of Urology, University Medical Center Goettingen, Goettingen, Germany. · Chair of Spatial Data Science and Statistical Learning, Georg-August-University Goettingen, Goettingen, Germany.
Key points
From the paper's conclusion- Manual segmentation and ellipsoid-based approximation show good agreement, underscoring the practical utility of the ellipsoid approximation for routine prostate volume assessment. While inaccuracies increase for larger glands, individualized weighting offers no meaningful benefit, and diagnostic performance for PSA density remains largely unaffected.
Abstract
PURPOSE: To evaluate how accurately prostate volume estimated with the ellipsoid formula matches manual segmentation (reference standard) and to assess whether an individualized, volume-dependent adjustment of the ellipsoid weighting factor improves performance. METHODS: In this prospective study, patients with suspected prostate cancer (PCa) who underwent 3 T multiparametric MRI (T1WI, T2WI, DWI, DCE) between January 2022 and June 2023 were included. PSA values were obtained at imaging or within the preceding 4 weeks. Reference prostate volumes were derived from manual segmentation of all axial T2-weighted slices. Ellipsoid-based volumes were calculated per PI-RADS recommendations from sagittal and axial T2-weighted images using A × B × C × 0.52. RESULTS: Overall, 328 patients were analyzed (median age 68 years), including 196 without and 132 with PCa. Ellipsoid-based volumes showed excellent agreement with manual segmentation (ICC = 0.985; mean absolute difference 5.5 cc). Differences were larger in prostates > 80 cc, where the ellipsoid method tended to underestimate volume. Optimal volume-dependent weighting factors ranged from 0.50 to 0.54, but statistical modeling with variable weighting factors did not significantly improve model performance. For PSAd cut-offs of 0.1, 0.15, and 0.2 ng/mL/cc, the ellipsoid approximation achieved sensitivities of 0.86-0.95 and specificities of 0.88-0.97 compared with manual segmentation. CONCLUSION: Manual segmentation and ellipsoid-based approximation show good agreement, underscoring the practical utility of the ellipsoid approximation for routine prostate volume assessment. While inaccuracies increase for larger glands, individualized weighting offers no meaningful benefit, and diagnostic performance for PSA density remains largely unaffected. KEY POINTS: Question Does the fast PI-RADS ellipsoid method estimate MRI prostate volume accurately versus manual segmentation, and do errors affect PSA density decisions? Findings In 328 men, ellipsoid volumes correlated strongly with segmentation (ρ = 0.98), underestimated larger glands (> 80 cc), and coefficient tuning added no meaningful improvement. Clinical relevance Ellipsoid-based volumetry provides a rapid, reliable basis for mpMRI prostate and PSA density assessment in routine clinical practice, supporting biopsy and active-surveillance decisions without time-consuming segmentation, while recognizing slightly higher error in very large prostates.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Automated voxel-based prostate volumetry improves PSA density-based detection of clinically significant prostate cancer in the PSA gray zone: comparison with manual segmentation and the ellipsoid formula.Frontiers in digital health · 2026
- The effects of prostate volume and PI-RADS category on optimal PSA-density thresholds for biopsy decision-makingEuropean Radiology · 2026
- Association Between Prostate Volume and PI-RADS v2.1 Performance for Detecting Clinically Significant Prostate Cancer in Men in the PSA Gray Zone: A Retrospective Study.Cancer management and research · 2026
- Diagnostic Value of Artificial Intelligence-Based Multiparametric MRI for Prostate Cancer in Patients With PSA Levels in the Gray Zone.Archivos espanoles de urologia · 2026
- Prostate Imaging Standards for Screening Magnetic Resonance Imaging (PRISM): International Consensus Recommendations.JAMA oncology · 2026
- PSA density for clinically significant prostate cancer detection: a retrospective cohort study on the influence of age and prostate volume.World journal of urology · 2026