Evaluation of different artificial intelligence-based coronary artery calcium scoring algorithms in nongated chest computed tomography.
Ting Li, Xiaodie Xu, Keqing Hu, Kun Li, Xiao Sun, Guohai Su, Peiji Song
Shandong First Medical University, Shandong Academy of Medical Sciences, Jinan, Shandong Province, China. · Department of Medical Imaging, Shandong Second Medical University, Weifang, Shandong Province, China.
Key points
From the paper's conclusion- The two AI-based CACS systems, when applied to nongated chest CT, demonstrated consistency with manually measured CACS from ECG-gated coronary CTA. Software B showed superior accuracy compared to Software A. The correlation between CACS and the degree of vascular stenosis is influenced by vascular remodeling patterns, with positive remodeling reducing its consistency. Therefore, a comprehensive assessment of vascular stenosis should integrate vascular remodeling patterns and other diagnostic indicators.
Abstract
BACKGROUND: To compare the accuracy of coronary artery calcium scores (CACSs) automatically measured by two artificial intelligence (AI) systems on nonelectrocardiogram (ECG)-gated chest computed tomography (CT) and to investigate the relationship between CACS and the degree of coronary artery stenosis. MATERIALS AND METHODS: A retrospective study was conducted on 182 patients who underwent both ECG-gated Coronary computed tomography angiography (CTA) and non-ECG-gated chest CT. Images from all patients were processed using postprocessing software and two AI systems (Software A/B). The manually measured CACS by experienced physicians using ECG-gated Coronary CTA was used as the gold standard. The agreement between two AI systems and the gold standard was assessed using the intraclass correlation coefficient (ICC) and Bland-Altman analysis. In addition, Spearman's correlation analysis was performed to evaluate the relationship between CACS and the degree of coronary artery stenosis. RESULTS: Both AI systems demonstrated high ICCs for CACS measurement (0.90, 95% confidence interval [CI]: 0.871-0.926 for Software A; 0.96, 95% CI: 0.943-0.968 for Software B). The mean differences (95% limits of agreement) were 23.59 ± 442.35 for Software A and -80.35 ± 292.99 for Software B. Both systems showed good agreement in CACS measurement, with Software B exhibiting higher accuracy than Software A. Spearman's correlation analysis revealed weak-to-moderate positive correlations between CACS measured by different methods and the degree of coronary artery stenosis (r = 0.151-0.560, P < 0.05) across all coronary branches. CONCLUSION: The two AI-based CACS systems, when applied to nongated chest CT, demonstrated consistency with manually measured CACS from ECG-gated coronary CTA. Software B showed superior accuracy compared to Software A. The correlation between CACS and the degree of vascular stenosis is influenced by vascular remodeling patterns, with positive remodeling reducing its consistency. Therefore, a comprehensive assessment of vascular stenosis should integrate vascular remodeling patterns and other diagnostic indicators.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Validation of Artificial Intelligence-based Non-gated Chest CT for Coronary Artery Calcium Scoring Across Multiple CT Scanners.Journal of imaging informatics in medicine · 2026
- Optimizing AI-Derived CAC Volume Thresholds on Non-Gated Chest CT for Detection of Actionable Coronary Artery Calcium: A Validation Against Agatston Scoring and Radiologist Reporting.Journal of thoracic imaging · 2026
- AI-Based Low-Dose Chest CT Assessment of Coronary Artery Calcification Score: An Analysis of Accuracy-Relating Factors.Journal of imaging informatics in medicine · 2026
- Fully automatic coronary artery calcium score using CT and artificial intelligence: external validation on a danish populationEuropean Heart Journal · 2026
- Artificial Intelligence Detection of Aortic Valve Calcification on Routine Noncontrast Chest CT: A Real-World Cohort.JACC. Advances · 2026
- Opportunistic Assessment of Coronary Artery Calcium Volume and Density From Non-Electrocardiogram-Gated Chest CT Using Artificial Intelligence: Prognostic Implications in a Screening CohortKorean Journal of Radiology · 2026