Dosimetric and Treatment Delivery Efficiency Comparison of Two Ring-gantry Linear Accelerator Platforms for Liver Stereotactic Body Radiotherapy.
Srikanth Guduru, Rohith Singareddy, N V N Madhusudhana Sresty, Deleep Kumar Gudipudi, Aparna Dode
Department of Radiotherapy, Basavatarakam Indo American Cancer Hospital and Research Institute, Hyderabad, Telangana, India. · Department of Radiation Oncology, Basavatarakam Indo American Cancer Hospital and Research Institute, Hyderabad, Telangana, India.
Key points
From the paper's conclusion- Both Tomotherapy and Halcyon are capable of generating high-quality liver SBRT plans with comparable target coverage. However, Halcyon demonstrated improved normal tissue sparing and enhanced treatment efficiency.
Abstract
PURPOSE: The purpose of this study was to compare the dosimetric performance and treatment delivery efficiency of two ring-gantry linear accelerator platforms, Helical Tomotherapy and Halcyon, in stereotactic body radiation therapy (SBRT) for liver metastasis. MATERIALS AND METHODS: A retrospective dosimetric analysis was conducted on 16 patients with solitary liver metastasis. For each patient, SBRT plans were generated using the Accuray treatment planning system (TPS) (Tomotherapy) and Eclipse TPS (Halcyon). Plan evaluation included conformity, homogeneity, and gradient indices, along with target coverage and organs at risk (OAR) dose-volume parameters, in accordance with Radiation Therapy Oncology Group-1112 (RTOG-1112) guidelines. Treatment efficiency was assessed using monitor units (MU) and beam-on time (BOT). Statistical analysis was performed using paired t-tests (SPSS v28.0), with P < 0.05 considered statistically significant. RESULTS: Both platforms achieved acceptable target coverage and OAR constraints. Conformity index and gradient index were comparable. Halcyon showed improved planning target volume homogeneity, lower normal liver V15 Gy, reduced OAR doses, and significantly lower MU and BOT (P < 0.05), indicating superior treatment efficiency. CONCLUSION: Both Tomotherapy and Halcyon are capable of generating high-quality liver SBRT plans with comparable target coverage. However, Halcyon demonstrated improved normal tissue sparing and enhanced treatment efficiency.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- TrueBeam vs Halcyon: Optimizing dual-LINAC scheduling through comparative dosimetric analysis.Medical dosimetry : official journal of the American Association of Medical Dosimetrists · 2026
- Log file-based treatment efficiency analysis of TrueBeam and Halcyon delivery systems.Journal of applied clinical medical physics · 2026
- Clinical applications of the Halcyon O-ring linear accelerator in radiation therapy: a systematic review of treatment efficacy, workflow efficiency, and imaging integration.Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2026
- Lesion Load Matters: Low-dose Spillage, Oar Impact, and Delivery Efficiency Across Robotic Radiosurgery, Ring-gantry, and C-arm Modalities in Multimetastatic Brain Stereotactic Radiotherapy.Clinical oncology (Royal College of Radiologists (Great Britain)) · 2026
- Influence of Delivery Geometry and Beam Modulation on Dose Gradient and Organ-at-Risk Sparing in Lung SBRT: A Comparative Planning StudyPolish Journal of Medical Physics and Engineering · 2026
- Two-center comparison of dedicated and general-purpose treatment planning for stereotactic body radiotherapy of spinal metastases with simultaneous integrated boost.Zeitschrift fur medizinische Physik · 2026