TrueBeam vs Halcyon: Optimizing dual-LINAC scheduling through comparative dosimetric analysis.
Sophie Hardie, Carlos Mesa Castrillon, Shiaw Juen Tan, Yae Joo Jun, Bridgitte Evans, Georgia Shortis, Rachael Beldham-Collins
Central West Cancer Centre, Orange Health Service, Orange, New South Wales, 2800, Australia. Electronic address: sophie.hardie@health.nsw.gov.au. · School of Rural Health, The University of Sydney, Dubbo, New South Wales, 2830, Australia.
Key points
From the paper's conclusion- Halcyon demonstrated dosimetric and efficiency advantages for free breathing breast, head & neck, and brain/head treatments.
Abstract
To compare dosimetric outcomes and treatment delivery times between the HalcyonTM and TrueBeamTM linear accelerators (LINACs: Varian Medical Systems, Palo Alto, CA) across 6 tumor sites ranging from complex head & neck to palliative cases, and to identify sites that may benefit from preferential Halcyon scheduling to optimize departmental workflow. This 2-phase study evaluated head & neck, chest/abdomen, prostate (±nodes), brain/head, free breathing breast, and palliative cases. Phase 1 was a retrospective paired dosimetric comparison of 60 patients (n = 10/site) treated between January 2023 and July 2025. Each patient had dual treatment plans created for Halcyon (6 MV FFF) and TrueBeam (6 MV or 10 MV) using Eclipse v16.1 with VMAT or IMRT techniques. Plans were assessed for planning target volume (PTV) coverage and organ-at-risk (OAR) mean (Dmean) and maximum (Dmax) doses. Phase 2 prospectively recorded treatment times (imaging initiation to final beam delivery) in 120 patients (n = 20/site) treated on both LINACs. Statistical comparisons used the Wilcoxon signed rank test (p < 0.05). Halcyon achieved slightly higher PTV coverage (97.88% vs 97.63%; p = 0.037) and significantly lower OAR mean and maximum doses (p ≤ 0.001). Site specific dosimetric advantages were observed for free breathing breast (OAR D̄mean: p < 0.001; Dmax: p = 0.039), Head & Neck (OAR D̄mean: p = 0.036), Prostate ±Nodes (OAR D̄mean: p = 0.008) and Brain/Head (OAR Dmax: p = 0.032). No significant dosimetric differences were identified for chest/abdomen or palliative cases. Halcyon also demonstrated shorter overall treatment delivery times, with statistically significant reductions for free breathing breast, head & neck, and brain/head. Halcyon demonstrated dosimetric and efficiency advantages for free breathing breast, head & neck, and brain/head treatments. Prioritizing these cases on the Halcyon linac may improve workflow efficiency and resource utilization. A LINAC allocation decision tree was developed to support clinical scheduling.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Log file-based treatment efficiency analysis of TrueBeam and Halcyon delivery systems.Journal of applied clinical medical physics · 2026
- Clinical applications of the Halcyon O-ring linear accelerator in radiation therapy: a systematic review of treatment efficacy, workflow efficiency, and imaging integration.Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2026
- Dosimetric and Treatment Delivery Efficiency Comparison of Two Ring-gantry Linear Accelerator Platforms for Liver Stereotactic Body Radiotherapy.Journal of medical physics · 2026
- Assessing the feasibility of uTPS for volumetric modulated arc therapy treatment plan optimization of dual-layer multileaf collimator linear accelerators.Radiation oncology (London, England) · 2026
- Updated dosimetric comparison of HDR interventional radiotherapy including 60Co sources versus VMAT and electron beam therapy for NMSC.Radiation and environmental biophysics · 2026
- Clinical impact of enhanced leaf modelling on multi-metastatic intracranial SRT delivered on Halcyon: a modest but consistent dosimetric effect.Physical and engineering sciences in medicine · 2026