Influence of intraoral and laboratory scanning systems on the marginal fit of direct metal laser-sintered copings: An in vitro study.
P S Prakhyath, Bharath Prabhu, Shijal Narayan Suvarna
Department of Prosthodontics and Implantology, A J Institute of Dental Sciences, Mangaluru, Karnataka, India. · Department of Prosthodontics and Implantology, Srinivas Institute of Dental Sciences, Mangaluru, Karnataka, India.
Key points
From the paper's conclusion- Copings fabricated from dies scanned using IOS demonstrated significantly lower vertical marginal discrepancies compared to those scanned using the laboratory scanner. However, the marginal gaps observed in both groups were within clinically acceptable limits.
Abstract
AIM: This study aimed to evaluate and compare the vertical marginal discrepancy of DMLS copings fabricated from stone dies scanned using an intraoral scanner (IOS) and a laboratory scanner. SETTINGS AND DESIGN: An in vitro comparative study was conducted to evaluate the influence of intraoral and laboratory scanning systems on the vertical marginal discrepancy of DMLS copings. MATERIALS AND METHODS: A customised stainless-steel model simulating a prepared tooth with a shoulder finish line was fabricated. Impressions of the model were made using elastomeric impression material. Forty dies ( n =40) were poured using type IV dental stone and divided into two groups ( n =20). Group 1 dies were scanned using a 3Shape TRIOS IOS and Group 2 dies were scanned using a 3Shape extraoral laboratory scanner. Copings were fabricated using CAD/CAM software. Marginal gap between the die and the coping was measured at 4 predetermined points (buccal, lingual, mesial, and distal) using a stereomicroscope at ×40 magnification. STATISTICAL ANALYSIS USED: Data were analysed using SPSS (version 21, IBM Corp., Armonk, NY, USA). Student's unpaired t-test was used to compare the tested groups. The collected data were analysed at a significance level set at P < 0.05. RESULTS: The mean marginal gap between the die and coping was 11.44 μm for Group 1 and 29.62 μm for Group 2. The difference between the groups was statistically significant ( P < 0.001). CONCLUSION: Copings fabricated from dies scanned using IOS demonstrated significantly lower vertical marginal discrepancies compared to those scanned using the laboratory scanner. However, the marginal gaps observed in both groups were within clinically acceptable limits.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Evaluation and comparison of the scanning accuracy of three intraoral scanners for single crown, three-unit, and cross-arch fixed partial denture by three-dimensional digital superimposition technique and measurement of vertical marginal fit of three-dimensional-printed resin retainers: An in vitro study.Journal of Indian Prosthodontic Society · 2026
- Limitations of RMS error in evaluating intraoral scanner accuracy: Comparison with linear and angular distortions from an enhanced metrology protocol.The Journal of prosthetic dentistry · 2026
- Marginal and internal fit accuracy of single-crown restorations: the impact of digital and conventional impression techniquesBMC Oral Health · 2025
- Accuracy of full-arch implant scan with Nexus IOS® scan gauges versus different conventional scan bodies: An in vitro comparative studyJournal of Dentistry · 2025
- Circular comparison of finish lines obtained from digital scans and conventional impressions: A clinical study.The Journal of prosthetic dentistry · 2026
- Accuracy of digital impressions captured by an intraoral scanner in a partially edentulous mandible.Journal of dental sciences · 2026