Circular comparison of finish lines obtained from digital scans and conventional impressions: A clinical study.
Heng Chen, Shaza Bishti, Sven Reich
Doctoral student, Department of Prosthodontics and Biomaterials, RWTH University Hospital, Aachen, Germany. · Attending and Master of Science, Department of Prosthodontics and Biomaterials, RWTH University Hospital, Aachen, Germany.
Key points
From the paper's conclusion- The results of this study suggest that digital scans may not capture subgingival preparation margins with the same accuracy as conventional methods.
Abstract
STATEMENT OF PROBLEM: Clinical studies that have investigated whether intraoral scanners (IOSs) are equivalent or even superior to conventional impressions in capturing subgingival finish lines are sparse. PURPOSE: The purpose of this clinical study was to compare circumferentially the course of subgingival chamfer preparations captured by both digital scans (DIGI) and conventional impressions (CONI) using CONI as reference. MATERIAL AND METHODS: Sixteen patients with a total of 50 teeth requiring crown preparations were included. For each die, a conventional polyether double-mix impression was made for the CONI workflow, and an intraoral scan was obtained for the DIGI setup. The CONI definitive casts were digitized, and the finish lines of the dies were defined for both workflows. The corresponding CONI and DIGI dies were registered. The deviations of the finish lines were analyzed circumferentially using an inspection software program with CONI as the reference. Positive (apical) and negative (coronal) deviations were calculated. Descriptive statistics were computed, normality was assessed using the Shapiro-Wilk test, and differences among tooth regions were analyzed using a linear mixed-effects model (α=.05). RESULTS: On average, 9% of the DIGI finish lines were apical relative to the CONI margins, with a mean ±standard deviation of 68 ±54 µm. In contrast, 91% of the DIGI finish lines were located coronally, with a mean ±standard deviation of 245 ±108 µm. There were no statistically differences among tooth regions (P>.05). CONCLUSIONS: The results of this study suggest that digital scans may not capture subgingival preparation margins with the same accuracy as conventional methods.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Influence of margin level and finish line geometry on the trueness of digital scans.The journal of advanced prosthodontics · 2026
- Comparative Evaluation of Tooth Type and Pulp Chamber Depth on the Accuracy of Endocrown Scans Acquired Using Various Intraoral Scanners.Journal of esthetic and restorative dentistry : official publication of the American Academy of Esthetic Dentistry ... [et al.] · 2026
- Accuracy of Direct Intraoral Versus Reverse Scanning for Abutment-Level Implant Impressions: an In Vitro Study.European journal of dentistry · 2026
- Accuracy of complete arch implant intraoral scans: A systematic review of different technique categories compared with the conventional splinted open tray method.The Journal of prosthetic dentistry · 2026
- Relative accuracy of intraoral photogrammetry and intraoral scanning with conventional scan-body for full-arch implants.Journal of prosthodontics : official journal of the American College of Prosthodontists · 2026
- Clinical Accuracy of Complete Arch Implant Scans Recorded by Using a Customized Metallic Ring-Based Calibrated Framework: An In Vivo Study.Clinical oral implants research · 2026