Evaluation and comparison of the scanning accuracy of three intraoral scanners for single crown, three-unit, and cross-arch fixed partial denture by three-dimensional digital superimposition technique and measurement of vertical marginal fit of three-dimensional-printed resin retainers: An in vitro study.
Mansi Dhiran, Ajay Sabane, Abhijit Ashok Patil, Arti Gachake, Darshana Mundhe, Rupali Patil
Department of Prosthodontics and Crown and Bridge, Bharati Vidyapeeth Deemed to be University Dental College and Hospital, Pune, Maharashtra, India.
Key points
From the paper's conclusion- All three scanners delivered clinically acceptable results; 3Shape TRIOS 3 yielded the highest accuracy and best marginal adaptation. Accuracy and marginal fit deteriorated as prosthesis span increased.
Abstract
AIM: This study aims to evaluate and compare the scanning accuracy of three IOSs and measuring the vertical marginal fit of three-dimensional (3D) printed resin retainers for single crown, three-unit, and cross-arch fixed partial denture situations. SETTINGS AND DESIGN: Comparative In Vitro Study. MATERIALS AND METHODS: A maxillary Nissin typodont with prepared abutments at #13, #23, #25, #27, and #16 served as the master model. A calibrated Shining 3D laboratory scanner provided the reference standard tessellation language (control). Each IOS generated six scans ( n = 6/scanner; 18 test scans). Trueness and precision were derived by best-fit superimposition in Geomagic Design X. Fifty-four single-unit, three-unit, and cross-arch retainers were 3D-printed. Vertical marginal discrepancy was measured at mid-buccal and mid-lingual sites using a digital stereomicroscope (×20). STATISTICAL ANALYSIS USED: One-way ANOVA with Tukey's post-hoc test was used for comparisons among scanners and prosthesis spans. Pearson's correlation was used to assess the relationship between trueness and marginal fit, and Chi-square test was used to assess clinical acceptability. A P value ≤0.05 was considered statistically significant. RESULTS: 3Shape TRIOS 3 showed the highest trueness (28.5 ± 5.2 µm) and precision (18.2 ± 3.1 µm), followed by Medit i700 and Shining 3D Aoralscan 3 ( P < 0.001). Marginal discrepancy was lowest with 3Shape TRIOS 3 (52.4 ± 6.5 µm) and increased with span. A positive correlation was found between trueness and marginal fit ( r = 0.82; P < 0.001). Clinical acceptability was 100%, 94.4%, and 77.8% for 3Shape TRIOS 3, Medit i700, and Shining 3D Aoralscan 3, respectively ( P = 0.041). CONCLUSION: All three scanners delivered clinically acceptable results; 3Shape TRIOS 3 yielded the highest accuracy and best marginal adaptation. Accuracy and marginal fit deteriorated as prosthesis span increased.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Trueness and precision of 5 intraoral scanners under different conditions in arches: A 3D comparative in vitro analysis.Dental and medical problems · 2026
- Effect of scan calibrator morphologies on the accuracy of calibrated complete-arch implant intraoral scans: an in vitro study.Journal of dentistry · 2026
- Influence of implant scan body material and intraoral scanner system on the accuracy of three-unit implant scans.The Journal of prosthetic dentistry · 2026
- Accuracy of 3D-Scanned Full-Arch Dentition Versus 3D-Printed Models Generated Using Various 3D Printers Based on Linear Measurements.Cureus · 2026
- Influence of margin level and finish line geometry on the trueness of digital scans.The journal of advanced prosthodontics · 2026
- Scanner-Dependent Influence of Palatal Surface Acquisition on Trueness, Precision and Transverse Arch Reproduction During Maxillary Complete-Arch Intraoral Scanning.Journal of dentistry · 2026