Diagnostic ability of Cirrus anterior segment optical coherence tomography to differentiate between binary grades of narrow angles seen on gonioscopy.
Vidya Chelerkar, Vidhi Solanki, Vks Kalyani, Nikita Patil
Department of Glaucoma, PBMA's H. V. Desai Eye Hospital, Pune, Maharashtra, India.
Key points
From the paper's conclusion- Discrimination capability of ASOCT parameters appears to be limited for differentiating between various grades of narrow angle. Further studies with larger sample sizes are required to study the utility of ASOCT in this aspect.
Abstract
PURPOSE: To assess diagnostic performance of Cirrus Anterior Segment Optical Coherence Tomography (ASOCT) parameters to differentiate gonioscopic grades of narrow angles. METHODS: This prospective cross sectional study included 100 eyes with clinically diagnosed angle closure disease. Quantitative ASOCT parameters such as angle width, angle opening distance (AOD), trabecular iris space area (TISA) at scleral spur distances of 500 and 750µm were measured.Shaffer's grading system was used to grade narrow angles. Area under the receiver operating characteristic curves (AUCs) were generated to assess diagnostic performance of these measurements to differentiate grades of narrow angles. RESULTS: 68 eyes were available for analysis. . Correlation between grade 0/1 on gonioscopy with 0-10° on ASOCT was seen in 81.3% of eyes in the nasal angle and 76.1% of eyes in the temporal angle ( P < 0.001), and grade 2 angle with 11-20° on ASOCT was seen in 80.0% of eyes in the nasal angle and 72.7% eyes in temporal angle ( P < 0.001). AUC for grade 0/1 and grade 2 angles on gonioscopy was highest for AOD500 nasally (0.80 [95% confidence interval (CI), 0.68-0.88]) while temporally, it was highest for TISA500 (0.72 [95% CI, 0.60-0.82]). Kappa coefficient between gonioscopy vs ASOCT was found to be 0.57 (95% CI, 0.36-0.75) nasally and 0.46 (95% CI, 0.24-0.67) temporally. CONCLUSION: Discrimination capability of ASOCT parameters appears to be limited for differentiating between various grades of narrow angle. Further studies with larger sample sizes are required to study the utility of ASOCT in this aspect.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Quantitative Assessment of Anterior Segment OCT Parameters and Their Association with Intraocular Pressure in Primary Angle-Closure Disease.Diagnostics (Basel, Switzerland) · 2026
- Quantitative Assessment of Schlemm's Canal Morphology and Observer Variability Using Swept-Source as-OCT in Healthy Eyes with Open and Narrow Angles.Clinical ophthalmology (Auckland, N.Z.) · 2026
- Circumferential Identification of Peripheral Anterior Synechiae by Air-Puff Dynamic Anterior Segment Optical Coherence Tomography.Translational vision science & technology · 2026
- Agreement of Anterior Segment Biometrics Measured Using Image-Registered Swept-Source OCT and High-Frequency Ultrasound Biomicroscopy.Journal of glaucoma · 2026
- Development and Clinical Evaluation of an Anterior Chamber Angle-Based Lens Sizing Method for Implantable Collamer Lens Surgery.Clinical ophthalmology (Auckland, N.Z.) · 2026
- Correlation between anterior segment optical coherence tomography parameters and visual field results after a single episode of acute angle closure glaucoma.Journal francais d'ophtalmologie · 2026