Diagnostic yield of Humphrey visual field 30-2 testing for neurological versus non-neurological visual disorders: A tertiary-care retrospective study.
Priti Singh, Samendra Karkhur, Vidhya Verma, Saroj Gupta, Rama Tulasi Siri Duddumpudi
Department of Ophthalmology, All India Institute of Medical Sciences (AIIMS), Bhopal, Madhya Pradesh, India.
Key points
From the paper's conclusion- HVF 30-2 perimetry demonstrates high diagnostic yield for neurological disorders and serves as a reliable, noninvasive functional investigation for neuro-ophthalmic evaluation.
Abstract
PURPOSE: To evaluate the diagnostic yield of Humphrey visual field (HVF) 30-2 automated perimetry in differentiating neurological from non-neurological causes of visual dysfunction. METHODS: Design: Retrospective observational record-based study. Setting: Department of Ophthalmology at a tertiary-care referral institute in Central India. Study population: All HVF tests performed between July 2023 and June 2025 were reviewed. Of 1,438 tests performed, 383 reliable HVF tests using the 30-2 program with the Swedish Interactive Threshold Algorithm (SITA) Standard or SITA Fast strategy were included. Tests with fixation losses >20%, false positive or negative responses >15%, incomplete records, or media opacities were excluded. Observation procedure: Visual field tests were categorized according to indication as neurological or non-neurological causes. Field patterns were analyzed and correlated with clinical findings and neuroimaging results. Main outcome measure: The primary outcome was diagnostic yield, defined as the proportion of HVF (30-2 program) contributing to confirmation of neurological disease. RESULTS: Among 383 HVF 30-2 tests, 226 (59.0%) were performed for neurological indications. Abnormal fields were detected in 132/226 (58.4%) neurological cases compared with 42/157 (26.8%) non-neurological cases (P < 0.001; odds ratio [OR] 3.84; 95% confidence interval [CI]: 2.48-5.95). Confirmed neurological diseases were identified in 118 (52.2%) neurological referrals versus 3 (1.9%) non-neurological referrals (OR 56.6; 95% CI: 17.4-184.0). Bitemporal hemianopia (23.5%), homonymous hemianopia (19.7%), and central scotoma (16.7%) were the most common field patterns, with >90% radiological correlation. HVF 30-2 testing demonstrated high diagnostic performance for neurological disorders (OR 56.6; 95% CI: 17.4-184.0; P < 0.001). CONCLUSION: HVF 30-2 perimetry demonstrates high diagnostic yield for neurological disorders and serves as a reliable, noninvasive functional investigation for neuro-ophthalmic evaluation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Pilot Study to Compare a Portable Tablet Perimeter with Humphrey Field Analyzer in Patients with Neuro-Ophthalmic Disorders.Journal of binocular vision and ocular motility · 2026
- Automated perimetry in pediatric neuro-ophthalmic conditions: virtual reality-based vs. standard tabletop platforms.American journal of ophthalmology · 2026
- Use of a Virtual Reality Visual Field Device to Improve Quality of Care in the Emergency Department and Inpatient Setting.Journal of neuro-ophthalmology : the official journal of the North American Neuro-Ophthalmology Society · 2026
- Clinical Spectrum of Neuro-Ophthalmic Disorders at a Thai Tertiary Referral Center: An 11-Year Retrospective Study.Clinical ophthalmology (Auckland, N.Z.) · 2026
- Evaluation of the Perimouse Online Suprathreshold Visual Field Test for Glaucoma Screening in a Chinese Population: A Comparison with the Humphrey Field Analyzer.Clinical ophthalmology (Auckland, N.Z.) · 2026
- Diagnostic challenges in suspected optic neuritis: a 5-year retrospective application of the 2022 international criteria.Multiple sclerosis and related disorders · 2026