Indian journal of ophthalmology

Intermediate and near vision outcomes with an advanced monofocal aspheric Swiss Phob intraocular lens.

Murugesan Kumaran, V G Madanagopalan, Madhivanan Nivean, Nivean Pratheeba

Department of Cataract and Refractive Surgery, Kumaran Eye Speciality Center, Choolaimedu, Chennai, Tamil Nadu, India. · Department of Cataract and Vitreoretina Services, JB Eye Hospital, Salem, Tamil Nadu, India.

Observational · n=60

Key points

From the paper's conclusion
  • The Swiss Phob advanced monofocal IOL provides good distance and intermediate visual acuity with functional near vision. The significant reciprocal association between uncorrected intermediate and near visual acuity suggests an extended range of functional vision across intermediate and near distances.

Abstract

PURPOSE: To evaluate postoperative visual outcomes at distance, intermediate, and near and determine correlation between intermediate and near vision following implantation of an advanced monofocal aspheric Swiss Phob intraocular lens (IOL). METHODS: This retrospective observational study included 60 eyes of 30 patients who underwent bilateral cataract surgery with Swiss Phob IOL implantation before May 2024. Postoperative evaluation at 6-12 months included uncorrected distance (UDVA), intermediate (UIVA), and near visual acuity (UNVA). Subgroup analysis based on UIVA and UNVA outcomes and correlation analysis were performed. Contrast sensitivity (CS) and defocus curves were assessed. RESULTS: Mean UDVA improved from 0.60 ± 0.31 to 0.22 ± 0.12 logMAR ( P < 0.001), and UNVA improved from 0.27 ± 0.12 to 0.18 ± 0.05 logMAR ( P < 0.001). Mean postoperative UIVA was 0.14 ± 0.16 logMAR. Eyes with UIVA had significantly superior UNVA ( P = 0.009), and eyes with better UNVA had significantly superior UIVA ( P = 0.037). A positive correlation was observed between UIVA and UNVA (r = 0.42, P < 0.05). The residual refractive error was minimal (-0.30 ± 0.47 D), with a target refraction of ± 0.50D attained in 80% (48) eyes and ± 1.00D attained in 93.3% (56) eyes. CS was 1.55 ± 0.19 (1.05-1.95) when assessed unilaterally. CS improved when assessed bilaterally to 1.71 ± 0.17. CONCLUSION: The Swiss Phob advanced monofocal IOL provides good distance and intermediate visual acuity with functional near vision. The significant reciprocal association between uncorrected intermediate and near visual acuity suggests an extended range of functional vision across intermediate and near distances.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers