Centration and Torsion Control Following Lenticule Creation With Keratorefractive Lenticule Extraction: Effect on Aberration and Astigmatism.
Ashton Z Lau, Jaycie Koh, Nicole M Sie, Ashraf Mahmoud, Yu-Chi Liu, Cynthia J Roberts, Jodhbir S Mehta
Regenerative Therapy Group, Singapore Eye Research Institute, Singapore. · Department of Ophthalmology & Visual Sciences, The Ohio State University Wexner Medical Center, Columbus, Ohio.
Key points
From the paper's conclusion- Semi-automated centration and cyclotorsion control in SILK allows for precise alignment with comparative results to non-adjusted cases with respect to refractive, astigmatic, optical zone, or higher order aberration outcomes at 12 months.
Abstract
PURPOSE: To evaluate the impact of the post-docking centration and cyclotorsion control functions of the ELITA femtosecond laser system (Johnson & Johnson Vision) on visual, refractive, and optical zone outcomes following Smooth Incision Lenticular Keratomileusis (SILK; Johnson & Johnson Vision). METHODS: This clinical study prospectively enrolled 59 eyes from 30 patients who underwent SILK at the Singapore National Eye Centre between May 2022 and May 2023. Surgeon decision determined whether eyes required post-docking manual centration or cyclotorsion adjustment. Functional optical zone (FOZ), decentration, astigmatism, and higher order aberrations were compared between the movement and no movement groups up to 12 months postoperatively. RESULTS: Centration and cyclotorsion adjustments were required in 29 of 59 eyes (49.2%). Mean movement was 0.07 mm superior and 0.13 mm nasal, and mean cyclotorsion was 4.3° counterclockwise. Suction time showed a borderline significant association with adjustment (P = .050). At 12 months, postoperative spherical equivalent, astigmatism, higher order aberrations, and FOZ did not differ significantly between groups. Mean FOZ area was 27.67 ± 3.17 mm2 (movement) and 28.56 ± 3.54 mm2 (no movement) (P = .35). All eyes achieved an uncorrected distance visual acuity of 20/40 or better; 66% and 53% achieved 20/20 or better in the movement and no movement groups, respectively (P = .492). No intraoperative or postoperative complications occurred. CONCLUSIONS: Semi-automated centration and cyclotorsion control in SILK allows for precise alignment with comparative results to non-adjusted cases with respect to refractive, astigmatic, optical zone, or higher order aberration outcomes at 12 months.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Incision-induced astigmatic changes in eyes undergoing simultaneous phakic intraocular lens explantation and phacoemulsificationJournal of Cataract & Refractive Surgery · 2026
- Comparison of Treatment Zone Decentration Between VISUMAX 500 and VISUMAX 800 Keratorefractive Lenticule Extraction Using Anterior Segment Optical Coherence Tomography.Journal of clinical medicine · 2026
- Astigmatic vector outcomes after FS-LASIK versus SMILE for high myopic astigmatism: a single-center retrospective comparative cohort study without cyclotorsion compensation.International ophthalmology · 2026
- Micro-scale Decentration and Axis-Specific Optical Aberrations After Keratorefractive Lenticule Extraction With the VisuMax 800: Clinical Relevance of a 0.1-mm Threshold on Optical Quality.Journal of refractive surgery (Thorofare, N.J. : 1995) · 2026
- Scan Geometry Orientation Influences Early Visual Acuity After Low-Energy Keratorefractive Lenticule Extraction: A Randomized Contralateral-Eye Study.Journal of refractive surgery (Thorofare, N.J. : 1995) · 2026
- Viscoelastic-Assisted Patient Interface Docking: A Technical Optimization in LenSx Femtosecond Laser-Assisted Cataract Surgery.Journal of refractive surgery (Thorofare, N.J. : 1995) · 2026