Astigmatic vector outcomes after FS-LASIK versus SMILE for high myopic astigmatism: a single-center retrospective comparative cohort study without cyclotorsion compensation.
Yinan Liu, Tao Chen, Bo Qu, Xiaoyong Chen
Department of Ophthalmology, Peking University Third Hospital, 49th North Garden Road, Haidian District, Beijing, 100191, China. · Beijing Fenglian Jiayue Lige Clinic, 18th Chaoyangmen Outer Street, Chaoyang District, Beijing, 100020, China.
Key points
From the paper's conclusion- Under surgical alignment without cyclotorsion compensation, FS-LASIK and SMILE/KLEx both yielded acceptable visual and refractive safety/efficacy for high myopic astigmatism (- 2.00 to - 3.75 D) at 1-year follow-up, but demonstrated divergent astigmatism correction tendencies: FS-LASIK exhibited relative astigmatism overcorrection (vector mean DV: - 0.35 ± 0.43 D × 91°, CI > 1), while SMILE/KLEx showed relative undercorrection (vector mean DV: - 0.21 ± 0.53 D × 12°, CI < 1). These correction biases are specific to the study's manual limbal alignment protocol without cyclotorsion tracking and cannot be generalized to modern optimized surgical platforms equipped with automated cyclotorsion compensation. Residual refractive errors across both groups are likely multifactorial, including differential corneal stromal healing responses, divergent femtosecond/excimer laser tissue modification mechanisms, and uncorrected intraoperative ocular cyclotorsion.
Abstract
PURPOSE: To compare astigmatic correction vector outcomes between femtosecond laser-assisted in situ keratomileusis (FS-LASIK) and small-incision lenticule extraction (SMILE, also termed Keratorefractive Lenticule Extraction, KLEx) without intraoperative cyclotorsion compensation in patients with high myopic astigmatism (- 2.00 to - 3.75 D), and to clarify procedure-specific correction tendencies under this non-standardized alignment protocol. METHODS: This single-center retrospective comparative cohort study enrolled 155 eyes (one eye randomly selected per patient) that underwent FS-LASIK (80 eyes) or SMILE/KLEx (75 eyes) for high myopic astigmatism correction from January 2023 to July 2024 in Beijing Fenglian Jiayue Lige Clinic. Intraoperative cyclotorsion compensation was intentionally disabled to isolate inherent procedural astigmatism correction characteristics. Standardized Alpins vectorial analysis was performed at 3 months and 12 months postoperatively. PRIMARY ENDPOINT: 12-month Alpins correction index (CI). Multivariable propensity score adjustment was applied to mitigate confounding by clinical treatment selection bias. Statistical multiplicity control was implemented for secondary vector and visual outcomes. RESULTS: Baseline demographic, refractive, corneal and ocular biometric parameters were balanced between groups after propensity matching. No statistically significant intergroup differences were detected in uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), residual cylinder, safety index or efficacy index at 3 and 12 months (all P > 0.05). Under the non-cyclotorsion-compensated protocol, significant intergroup differences were identified in the magnitude of surgically induced astigmatism (SIA), correction index (CI), and magnitude error (ME) at both follow-up timepoints (all P < 0.0001). Target induced astigmatism (TIA), difference vector (DV), index of success (IOS), and angle error (AE) magnitudes were comparable between groups (all P > 0.05). The vector mean axis of DV differed significantly between groups at 3 and 12 months (Watson-Williams circular test, all P < 0.0001). No reoperations were documented in clinic medical records for either cohort. No standardized dry eye questionnaires, tear film testing or corneal nerve density metrics were collected to quantify dry eye adverse events; only unstructured clinical notes were reviewed for complication screening. CONCLUSIONS: Under surgical alignment without cyclotorsion compensation, FS-LASIK and SMILE/KLEx both yielded acceptable visual and refractive safety/efficacy for high myopic astigmatism (- 2.00 to - 3.75 D) at 1-year follow-up, but demonstrated divergent astigmatism correction tendencies: FS-LASIK exhibited relative astigmatism overcorrection (vector mean DV: - 0.35 ± 0.43 D × 91°, CI > 1), while SMILE/KLEx showed relative undercorrection (vector mean DV: - 0.21 ± 0.53 D × 12°, CI < 1). These correction biases are specific to the study's manual limbal alignment protocol without cyclotorsion tracking and cannot be generalized to modern optimized surgical platforms equipped with automated cyclotorsion compensation. Residual refractive errors across both groups are likely multifactorial, including differential corneal stromal healing responses, divergent femtosecond/excimer laser tissue modification mechanisms, and uncorrected intraoperative ocular cyclotorsion.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Automated Versus Image-Guided Cyclotorsion Control in FS-LASIK: A Vector Analysis Study.Current eye research · 2026
- Short-term comparative outcomes of toric ICL implantation versus femtosecond LASIK for myopic astigmatism.BMC ophthalmology · 2026
- Early postoperative objective residual astigmatism after femtosecond LASIK and toric implantable collamer lens implantation: a real-world overlap-weighted stratified comparison.International ophthalmology · 2026
- Comparison of the visual and optical outcomes after different corneal refractive surgeries for asymmetric corneal astigmatism.International ophthalmology · 2026
- Enhanced predictability and axis precision of SMILE Pro, a retrospective analysis of myopic astigmatism correction.International journal of ophthalmology · 2026
- Effects of FS-LASIK and ICL Implantation on Horizontal Phoria and Accommodation in Highly Myopic Eyes.Journal of the College of Physicians and Surgeons--Pakistan : JCPSP · 2026