Liquid chromatography-tandem mass spectrometry quantification of five antihistamines in antemortem blood: method validation and application.
Kenson Jean, Kristin W Kahl, Lisa J Reidy
Department of Pathology and Laboratory Medicine, Toxicology Laboratory, University of Miami Miller School of Medicine, Rosenstiel Medical Science Building, Miami, FL 33136, United States.
Key points
From the paper's conclusion- A liquid chromatography-tandem mass spectrometry method was developed and validated for five first-generation H1 antihistamines: chlorpheniramine, diphenhydramine, doxylamine, hydroxyzine, and promethazine.
Abstract
First-generation H1 antihistamines have central nervous system penetration and anticholinergic activity, with potential side effects including sedation, cognitive impairment, and anterograde amnesia. First-generation antihistamines pose risks in driving under the influence of drugs (DUID) and drug-facilitated crimes (DFC) forensic casework. A liquid chromatography-tandem mass spectrometry method was developed and validated for five first-generation H1 antihistamines: chlorpheniramine, diphenhydramine, doxylamine, hydroxyzine, and promethazine. The calibration range was 1-200 ng/mL with a 1/x linear calibration model for quantitative compounds, and the limit of detection was determined to be 0.5 ng/mL for all compounds. Bias and precision were acceptable, with minor but acceptable suppression observed at low and high concentrations. No exogenous or endogenous interferences were observed. Carryover was not detected after a 400 ng/mL sample. Processed samples were determined to be stable 24 h after initial injection when stored in the refrigerated multi-sampler. Authentic forensic specimens from DUID and DFC investigations showed a wide range of concentrations for diphenhydramine. Selected case reports are presented to demonstrate the applicability of the method. The high percentage of polysubstance cases, range of concentrations, and delayed sample collection in DFC cases underscore the importance of a sensitive and reproducible method for these first-generation antihistamines, especially in human-performance casework.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Segmental Hair Analysis of Diphenhydramine and Cyclizine Following a Single DoseDrug Testing and Analysis · 2026
- Can a single dose of cetirizine and meclizine be quantified in hair up to one year after intake?Forensic science international · 2026
- Development and Validation of an HPLC-MS/MS Method for the Determination of Benzodiazepines in Hair. Comparison of Two Different Extractions and Applications on Real Samples.Drug testing and analysis · 2026
- Analysis of Histamine in Amino Acid Additives by Ultra-Performance Liquid Chromatography-Tandem Mass SpectrometryDOAJ (DOAJ: Directory of Open Access Journals) · 2026
- A Validated Multi-Analyte Liquid Chromatography-Tandem Mass Spectrometry Method for Simultaneous Therapeutic Drug Monitoring and Targeted Toxicological Assessment of 54 Drugs and Metabolites in Human Serum.Journal of separation science · 2026
- Development and validation of a UHPLC-MS/MS method for the simultaneous determination of 100 drugs in human hair.Journal of chromatography. B, Analytical technologies in the biomedical and life sciences · 2026