Modeling Blood Permittivity with a Modified Cole-Cole Framework.
Zaid A Abdul Hassain, Malik J Farhan, T A Oleiwi
Electrical Engineering Department, Mustansiriyah University. · Department of Automation and Artificial Intelligence Engineering, College of Information Engineering at Al-Nahrain University.
Key points
From the paper's conclusion- This study introduces a novel electromagnetic framework for modeling the dielectric response of blood to glucose variations, focusing on the real part of permittivity (ε') across 0.1-20 GHz.
Abstract
Accurate, non-invasive estimation of blood glucose and glycated hemoglobin (HbA1c) remains a key challenge in biomedical sensing. This study introduces a novel electromagnetic framework for modeling the dielectric response of blood to glucose variations, focusing on the real part of permittivity (ε') across 0.1-20 GHz. The HbA1c-related analysis was limited to the frequency range of 0.1-10 GHz. A modified Cole-Cole model is developed, expressing dielectric relaxation parameters as polynomial functions of glucose concentration, allowing precise reconstruction of broadband complex permittivity. A sensitivity extraction technique is proposed to compute the partial derivative of ε' with respect to glucose levels. Results reveal a critical frequency band 5-7 GHz where ε' demonstrates maximum sensitivity to glycemic variations, providing a basis for optimal frequency selection in sensor design. Additionally, a physiology-based model links permittivity to HbA1c levels, accounting for red blood cell turnover and glucose accumulation. This dual-focus modeling approach is, to our knowledge, the first to integrate glucose and HbA1c into a unified dielectric characterization using a modified Cole-Cole framework. The proposed method enables improved spectral targeting for microwave biosensors, offering enhanced resolution and biomedical relevance. This work paves the way for future development of multi-marker, real-time, non-invasive EM-based diagnostic systems.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Leaky-Wave Antenna for Non-Invasive Continuous Glucose MonitoringarXiv · 2026
- A Multifrequency Millimeter-Wave CMOS Sensor for Non-Invasive Continuous Glucose Monitoring Using UMC 0.18 μm Technology.Biosensors · 2026
- Experimental and Physics-Informed Deep-Learning-Enhanced Wearable Microwave Sensor for Non-Invasive Blood Glucose MonitoringElectronics · 2025
- Design of an Ultra-Sensitive Multi-Resonant Moore Fractal SRR Microwave Sensor for Non-Invasive Blood Glucose MonitoringSensors · 2026
- Innovative contactless dual-coupled microwave sensor for non-invasive blood glucose monitoringScientific Reports · 2026
- Machine Learning-Aided Microwave Sensing for Blood Glucose Detection: Data Information Enhancement from Reduced Measurement Set.Biosensors · 2026