Design of an Ultra-Sensitive Multi-Resonant Moore Fractal SRR Microwave Sensor for Non-Invasive Blood Glucose Monitoring
Zaid A. Abdul Hassain, Malik Jasim Farhan, Taha A. Elwi
Mustansiriyah University · Nahrain University
Key points
From the paper's conclusion- This study details the design and development of an ultra-sensitive microwave sensor for non-invasive blood glucose monitoring, achieved by analyzing variations in the response of a split-ring resonator (SRR) through advanced engineering methodologies.
Abstract
This study details the design and development of an ultra-sensitive microwave sensor for non-invasive blood glucose monitoring, achieved by analyzing variations in the response of a split-ring resonator (SRR) through advanced engineering methodologies. There were three design phases in the development process. In the first phase, a standard SRR design was used. It had a resonant frequency of 2.975 GHz in S21 and a sensitivity of only 0.0032 dB/(mg/dL). In the second phase, an interdigital capacitor (IDC) was added to the SRR structure. This made it work better and made it more sensitive, with a sensitivity of 0.015 dB/(mg/dL) at 4.1 GHz. The third phase was to use a fourth-order Moore fractal geometry to improve the resonance properties of the design a lot. From the obtained S11, the maximum sensitivity was 0.042 dB/(mg/dL), which was a huge improvement in sensing efficiency compared to earlier designs. Several resonant frequencies were recorded between 4.84 and 7.56 GHz. The addition of the fractal structure made the electromagnetic field stronger in the resonant space and made the waves interact more with small changes in the biological medium, all without changing the sensor’s size (80 mm × 40 mm). These results show that fractal architecture is a promising way to create non-invasive, accurate, and easily integrated sensors in biological systems that can continuously measure blood glucose levels.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Design and Optimization of an Inductive-Stub-Coupled CSRR for Non-Invasive Glucose SensingSensors · 2025
- A Multifrequency Millimeter-Wave CMOS Sensor for Non-Invasive Continuous Glucose Monitoring Using UMC 0.18 μm Technology.Biosensors · 2026
- A Dual-Form Spiral-like Microwave Sensor for Non-Invasive Glucose Monitoring: From Planar Design to Wearable ImplementationElectronics · 2026
- Innovative contactless dual-coupled microwave sensor for non-invasive blood glucose monitoringScientific Reports · 2026
- Development and experimental evaluation of single-port substrate integrated waveguide resonator with dual-parameter sensitivity for non-invasive blood glucose monitoringMeasurement · 2026
- High-Sensitivity Non-Invasive Microwave Glucose Sensor with ZnO/CNT Composite Optimized by Deep Learning for Wearable Medical Devices.ACS omega · 2026