Key points
From the paper's conclusion- We quantified 18F-Fluorodeoxyglucose (FDG) uptake in intrathoracic lymph nodes (ITLNs) of eleven interferon-gamma release assay (IGRA) positive TB contacts that enrolled on a prospective observational study, including eight contacts with serial PET-CT scans.
Abstract
Positron emission tomography-computed tomography (PET-CT) has shown potential as a research tool to characterize heterogeneity in tuberculosis (TB) infection. Prospective utilisation of this technology will require standardization of imaging protocols, interpretation, and analysis of PET-CT images to improve generalizability and data assimilation between discrete cohorts. We evaluated a semi-automated approach using open-source software to minimize inter-operator variability of imaging interpretation and use reference organ normalization to lower variability in physiological uptake. We quantified 18F-Fluorodeoxyglucose (FDG) uptake in intrathoracic lymph nodes (ITLNs) of eleven interferon-gamma release assay (IGRA) positive TB contacts that enrolled on a prospective observational study, including eight contacts with serial PET-CT scans. The imaging was analyzed using 3D Slicer, an open-source medical imaging platform designed for biomedical and clinical research, that provides semi-automated segmentation and automated liver quantification. The extracted data included ITLN maximum standardized uptake value (SUVmax), mean standardized uptake value (SUVmean), metabolic volume (MV), and total lesion glycolysis (TLG), and liver SUVmean. We compared its performance to that of clinical software, both with and without standardizing to liver uptake (as a physiological reference), and assessed operator variability. Then, we evaluated the association between multiple quantitative PET metrics and prospective outcomes in pulmonary TB contacts. We report strong agreement between open-source and clinical image evaluation platforms. We find semi-automated PET quantification can lower inter-operator variability, and standardizing to reference organs increases the sensitivity of imaging analysis. Specifically, we report preliminary findings that increasing metabolic activity on serial PET-CT in early infection is associated with detectable Mycobacterium tuberculosis (Mtb) at the anatomical site of FDG uptake, consistent with a progressive phenotype of infection.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- PET–CT benchmarked detection and 5-year progression of asymptomatic tuberculosis: a longitudinal, prospective cohort studyThe Lancet Respiratory Medicine · 2026
- Role of ¹⁸F-FDG PET/CT in monitoring treatment response in extrapulmonary tuberculosis: a retrospective observational study.Infection · 2026
- Quantifying [18F]FDG Uptake in the Liver, Spleen, Aorta, Bone Marrow, and Superior Vena Cava Using TotalSegmentator on [18F]PET/CT Imaging.Diagnostics (Basel, Switzerland) · 2026
- Clinical testing of drug treatment shortening in patients with TB using PET/CT imaging of lung lesionsScience Translational Medicine · 2026
- Automated long axial field of view PET image processing and kinetic modelling with the TurBO toolboxEuropean Journal of Nuclear Medicine and Molecular Imaging · 2026
- Role of [18F] FDG PET/CT in Critically Ill Patients: A Comprehensive Review for Clinical Practice.PET clinics · 2026