Quantifying [18F]FDG Uptake in the Liver, Spleen, Aorta, Bone Marrow, and Superior Vena Cava Using TotalSegmentator on [18F]PET/CT Imaging.
Tanja Fromberg Gorlen, Jane Maestri Brittain, Edvin Smajlovic, Flemming Littrup Andersen, Mikkel Østergaard, Peter Riis Hansen, Rasmus Sejersten Ripa, Lene Terslev
Copenhagen Center for Arthritis Research (COPECARE), Center for Rheumatology and Spine Diseases, Centre for Head and Orthopaedics, Rigshospitalet, 2600 Glostrup, Denmark. · Department of Clinical Physiology and Nuclear Medicine, Rigshospitalet, 2100 Copenhagen, Denmark.
Key points
From the paper's conclusion- We aimed to evaluate the agreement between manual delineation and automatic segmentation by the artificial intelligence model TotalSegmentator for extraction of standard uptake values (SUVs) from [18F]FDG-PET/CT scans for the aorta, spleen, lumbar spine bone marrow, liver, and superior vena cava.
Abstract
Background/Objectives: The measurement of radiotracer uptake in specific organs has potential clinical implications. However, manual delineation is time-consuming. We aimed to evaluate the agreement between manual delineation and automatic segmentation by the artificial intelligence model TotalSegmentator for extraction of standard uptake values (SUVs) from [18F]FDG-PET/CT scans for the aorta, spleen, lumbar spine bone marrow, liver, and superior vena cava. Methods: The aorta, spleen, lumbar spine bone marrow, liver, and superior vena cava were segmented manually by trained physicians and automatically by the TotalSegmentator version 2.4 software, and the correlations between SUV values obtained were assessed. Results: We found good agreement between manually and automatically obtained SUVmean values for the aorta (manual/TotalSegmentator: 2.10/2.11), spleen (2.00/1.95), liver (2.53/2.37), lumbar spine bone marrow (1.88/1.85), and superior vena cava (2.02/1.88) with high correlation coefficients across all organs, ranging from 0.93 to 0.99 and high intraclass correlation coefficients (ICCs) of 0.81-0.99. Agreement for SUVmax showed greater variability across the organs which were assessed: agreement was good for the spleen (ICC 0.83) and lumbar spine bone marrow (ICC 0.86), but weak for the aorta (ICC 0.11). Bland-Altman analyses for SUVmean indicated no systematic bias in the aorta or spleen, slight bias in bone marrow, liver, and superior vena cava, and variable bias for SUVmax across all structures. Conclusions: TotalSegmentator provided reliable SUVmean values from the aorta, spleen, lumbar spine bone marrow, liver, and superior vena cava. However, the agreement between manually and automatically obtained SUVmax values was variable, suggesting that additional quality control steps should be applied if using TotalSegmentator for SUVmax extraction.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Automated long axial field of view PET image processing and kinetic modelling with the TurBO toolboxEuropean Journal of Nuclear Medicine and Molecular Imaging · 2026
- Automated Vascular Segmentation in PET Imaging: From Technical Feasibility to Clinical Readiness, a Hands-On Scoping Review.Bioengineering (Basel, Switzerland) · 2026
- Agreement between AI-based automated and expert-defined manual whole-body tumor volume assessment in [¹⁸F]FDG-PET/CT of NSCLC patients.BMC medical imaging · 2026
- AI-based automated body composition analysis from whole-body MRI and (PET-) CT: an intermodal comparison from same-day examinations.Cancer imaging : the official publication of the International Cancer Imaging Society · 2026
- Fully Automated Segmentation of [18F]FDG and [68Ga]/[18F]PSMA PET/CT Images via Data-Centric Deep Learning.Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2026
- Evaluation of the detection accuracy of a fully automated AI-based lesion segmentation tool in whole-body FDG PET/CT for lymphoma.Zeitschrift fur medizinische Physik · 2026