科研速览 · Science Skim继续刷下去 · Keep skimming →
◆ European Journal of Nuclear Medicine and Molecular Imaging2026-01-31· Computer science

Automated long axial field of view PET image processing and kinetic modelling with the TurBO toolbox

Jouni Tuisku, Santeri Palonen, Henri Kärpijoki, Aino Latva‐Rasku, Nelli Tuomola, Harri Harju, Sergey V. Nesterov, Vesa Oikonen, Hidehiro Iida, Jarmo Teuho, Chunlei Han, Tomi Karjalainen, Anna K. Kirjavainen, Johan Rajader, Riku Klén, Pirjo Nuutila, Juhani Knuuti, Lauri Nummenmaa

原始摘要(英文原文)· Original abstract
Abstract Purpose Long axial field of view (LAFOV) PET imaging requires extensive automation due to the large number of target tissues. Therefore, we introduce an open-source analysis pipeline (TurBO, Turku total-BOdy) for automated preprocessing and kinetic modelling of LAFOV [ 15 O]H 2 O and [ 18 F]FDG PET data. TurBO enables efficient, reproducible quantification of tissue perfusion and metabolism at regional- and voxel-levels through automated co-registration, motion correction, CT-based region of interest (ROI) segmentation, image-derived input function (IDIF) extraction, and region-specific kinetic modelling. Methods The pipeline was validated with Biograph Vision Quadra (Siemens Healthineers) LAFOV PET/CT data from 21 subjects scanned with [ 15 O]H 2 O and 16 subjects scanned with [ 18 F]FDG. Six CT-segmented ROIs (cortical brain gray matter, left iliopsoas muscle, right kidney cortex and medulla, pancreas, spleen and liver) were used to assess different levels of tissue perfusion and glucose metabolism. Results Model fits showed high quality with consistent estimates at regional and voxel-levels (R 2 > 0.83 for [ 15 O]H 2 O, R 2 > 0.99 for [ 18 F]FDG). Manual and automated IDIFs were in concordance (R 2 > 0.74 for [ 15 O]H 2 O, and R 2 > 0.78 for [ 18 F]FDG) with minimal bias (< 4% and < 10%, respectively). Manual and CT-segmented ROIs showed strong agreement (R 2 > 0.82 for [ 15 O]H 2 O and R 2 > 0.83 for [ 18 F]FDG). Motion correction had little impact on estimates (R 2 > 0.71 for [ 15 O]H 2 O and R 2 > 0.78 for [ 18 F]FDG) compared with uncorrected data. Conclusion The TurBO pipeline provides fully automated and reliable quantification for LAFOV PET data. It substantially reduces manual workload and enables standardized, reproducible assessment of inter-organ perfusion and metabolism.
读原文 · Read the paper ↗

AI 追问PRO

登录后使用 AI 追问

讨论区

登录后参与讨论

相关论文 · Related

Automated long axial field of view PET image processing and kinetic modelling with the TurBO toolbox — 科研速览 Science Skim