Influence of hematocrit-dependent blood viscosity on hemodynamics of mitral paravalvular leak.
Igor Szumny, Magdalena Kopernik
AGH University of Krakow, Kraków, Poland.
Key points
From the paper's conclusion- The results demonstrate that hematocrit significantly influences hemodynamic conditions and hemolysis risk in mitral PVL.
Abstract
PURPOSE: Paravalvular leak (PVL) is a pathological condition that may arise following prosthetic mitral valve implantation and is characterized by regurgitant blood flow through a gap between the prosthetic valve ring and the native cardiac tissue. High-velocity flow jets generated within the leak region may produce elevated shear stresses capable of inducing mechanical damage to erythrocytes and subsequent hemolysis. The purpose of this study is to investigate the influence of blood viscosity, modulated by hematocrit variability, on flow characteristics and hemolytic potential in mitral PVL. METHODS: A computational fluid dynamics model was developed to simulate pulsatile blood flow through mitral PVL channel. The model included a time-varying left ventricular geometry, a kinematically constrained left atrium, and a simplified representation of a mechanical mitral valve with a localized paravalvular defect. Multiple physiological hematocrit levels were considered to account for viscosity variations. Non-Newtonian rheological behavior of blood was incorporated to capture shear-dependent viscosity effects. RESULTS: The simulations showed a strong dependence of shear stress on hematocrit. Increasing hematocrit led to higher effective viscosity, resulting in elevated shear stress levels within the PVL jet. A near-linear relationship between hematocrit and maximum shear stress was observed, with stress values exceeding the hemolysis threshold at higher hematocrit levels. Additionally, higher hematocrit values resulted in earlier onset of critical shear stress conditions. CONCLUSION: The results demonstrate that hematocrit significantly influences hemodynamic conditions and hemolysis risk in mitral PVL.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Methodology for computational assessment of hemolysis in under-occlusive roller pumps operated at clinically relevant conditions.Bioengineering & translational medicine · 2026
- Comparative Evaluation of Power-Law and Viscoelastic Hemolysis Models in the FDA Nozzle Benchmark Geometry.Cardiovascular engineering and technology · 2026
- Geometry-Dependent Wall Shear Stress in Standardized 50% Coronary Stenoses: Effects of Pressure and Hematocrit in a Parametric CFD StudyMathematical and Computational Applications · 2026
- A Viscosity Model for Blood Flows in Narrow Channels at High Reynolds Numbers Incorporating a Cell-Free Layer.Micromachines · 2026
- Paravalvular Leak After Transcatheter Aortic Valve Implantation: Haemodynamic Consequences, Clinical Impact, and Contemporary Assessment.Journal of cardiovascular development and disease · 2026
- Computational fluid dynamics assessment of a triple-lumen hemodialysis catheter.The journal of vascular access · 2026