Tebuconazole and penconazole - Determination of TEB-OH, TEB-COOH, PEN-OH, and PEN-COOH in urine by LC-MS/MS: Biomonitoring Method - Translation of the German version from 2026.
Elisa Polledri, Rosa Mercadante, Silvia Fustinoni, Laura Kuhlmann, Thomas Göen, Andrea Hartwig, MAK Commission
Laboratory of Environmental and Occupational Toxicology. Department of Clinical Sciences and Community Health. University of Milano and Fondazione IRCCS Ca Granda Ospedale Maggiore Policlinico Via Francesco Sforza 35 20122 Milano Italy. · Friedrich-Alexander-Universität Erlangen-Nürnberg. Institute and Outpatient Clinic of Occupational, Social, and Environmental Medicine Henkestraße 9-11 91054 Erlangen Germany.
Key points
From the paper's conclusion- The method is selective, sensitive, and provides quantitation limits of 0.3 μg/l for TEB-OH and TEB-COOH and of 1.0 μg/l for PEN-OH and PEN-COOH.
Abstract
The working group "Analyses in Biological Materials" of the German Senate Commission for the Investigation of Health Hazards of Chemical Compounds in the Work Area (MAK Commission) developed and verified this biomonitoring method for the measurement of the most important urinary metabolites of the triazole fungicides tebuconazole and penconazole. Specifically, this method determines (RS)-5-(4-chlorophenyl)-2,2-dimethyl-3-(1H-1,2,4-triazol-1-ylmethyl)-1,3-pentanediol (TEB-OH) and (RS)-5-(4-chlorophenyl)-2,2-dimethyl-3-(1H-1,2,4-triazol-1-ylmethyl)-3-olpentanoic acid (TEB-COOH) as well as 4-(2,4-dichlorophenyl)-5-[1,2,4]-triazol-1-ylpentanol (PEN-OH) and 4-(2,4-dichlorophenyl)-5-[1,2,4]-triazol-1-ylpentanoic acid (PEN-COOH) in urine. After adding isotope-labelled internal standards, the samples are enzymatically hydrolysed to release the analytes from the glucuronide and sulfate conjugates. After online purification, the analytes are separated by liquid chromatography and analysed using tandem mass spectrometry. Calibration is performed using calibration standards prepared in pooled urine and processed analogously to the samples to be analysed. The method provides reliable and accurate analytical results, as shown by the good precision data with standard deviations in the range of 0.1-10.7%. Good accuracy data were obtained with mean relative recoveries in the range of 100-107%. The method is selective, sensitive, and provides quantitation limits of 0.3 μg/l for TEB-OH and TEB-COOH and of 1.0 μg/l for PEN-OH and PEN-COOH.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Climbazole - Determination of dihydroxy-climbazole and carboxyhydroxyclimbazole in urine by UPLC-MS/MS: Biomonitoring Method - Translation of the German version from 2026.The MAK collection for occupational health and safety · 2026
- Dispersive micro-solid phase extraction of tebuconazole residues from orange juice using a graphene oxide-silica sorbent functionalized with a tailored ionic liquid.Food chemistry · 2026
- Biomass tomato pomace as a fluorescence probe for determination of toltrazuril in veterinary pharmaceuticals and milk samplesBMC Chemistry · 2026
- Metabolite-targeted LC-HRMS quantification of emerging indazole-based synthetic cannabinoids in urine samples from an addiction treatment cohort.Journal of chromatography. B, Analytical technologies in the biomedical and life sciences · 2026
- Ethoxyquin - Determination of 2,2,4-trimethyl-6(2H)-quinolinone in urine by UPLC-MS/MS: Biomonitoring Method - Translation of the German version from 2026.The MAK collection for occupational health and safety · 2026
- Acrylonitrile and N,N-dimethylformamide - Determination of S-(2-cyanoethyl)mercapturic acid and S-(N-methylcarbamoyl)mercapturic acid in urine by LC-MS/MS: Biomonitoring Method - Translation of the German version from 2026.The MAK collection for occupational health and safety · 2026