The MAK collection for occupational health and safety

Climbazole - Determination of dihydroxy-climbazole and carboxyhydroxyclimbazole in urine by UPLC-MS/MS: Biomonitoring Method - Translation of the German version from 2026.

Katja Küpper, Christoph Schmidtkunz, Isabell Schönrath, Wolfgang Gries, Gabriele Leng, Gerhard Scherer, Max Scherer, Kirsten Riedel,

Currenta GmbH & Co. OHG, CUR-SIT-ABG-GS-BLM - Institute for Biomonitoring Chempark Building Q18 51368 Leverkusen Germany. · ABF Analytisch-Biologisches Forschungslabor GmbH Semmelweisstraße 5 82152 Planegg Germany.

Key points

From the paper's conclusion
  • The working group "Analyses in Biological Materials" of the German Senate Commission for the Investigation of Health Hazards of Chemical Compounds in the Work Area (MAK Commission) developed and verified this analytical method for the determination of two important urinary metabolites of climbazole - dihydroxy-climbazole ((OH)2-climbazole) and carboxyhydroxyclimbazole (cx-OH-climbazole).

Abstract

The working group "Analyses in Biological Materials" of the German Senate Commission for the Investigation of Health Hazards of Chemical Compounds in the Work Area (MAK Commission) developed and verified this analytical method for the determination of two important urinary metabolites of climbazole - dihydroxy-climbazole ((OH)2-climbazole) and carboxyhydroxyclimbazole (cx-OH-climbazole). For the quantitation of the analytes, enzymatic hydrolysis of the urine sample is followed by online SPE‑UPLC‑MS/MS. The two diastereomers of (OH)2-climbazole are resolved chromatographically, and thus quantified separately. On the other hand, the diastereomers of cx-OH-climbazole coelute in one single peak. Calibration is performed using calibration standards prepared in pooled urine and processed analogously to the samples to be analysed. (OH)2‑climbazole-D6 and cx‑OH‑climbazole-D6 are applied as internal standards. The method provides reliable and accurate analytical results, as shown by the good precision data with standard deviations no greater than 9.2%. Good accuracy data were obtained with a mean relative recovery in the range of 96.9-102%. The method is both selective and sensitive, and provides a quantitation limit of 0.5 μg/l for (OH)2‑climbazole (per diastereomer) and cx‑OH‑climbazole (sum of diastereomers), respectively. The method enables the determination of occupational and environmental exposure to climbazole.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers