Accuracy of Guided Implant Surgery Using Tomographic Guides Combined with Functional Impression: An In Vitro Study.
Renata Bommarito, Yolanda de Toledo Salvado da Ressurreição, Luciana Akemi Yamaguchi, Flavia Iotti Fernandes, Eduardo Perissinotto, Marcos Venturini Ferreira, Marcio Katsuyoshi Mukai, Roger Nishyama,
Stomatology Department, University of São Paulo (USP), São Paulo, Brazil. · Prosthodontic Department, University of São Paulo (USP), São Paulo, Brazil.
Key points
From the paper's conclusion- The accuracy of implant positioning in edentulous maxillae was not significantly affected by the incorporation of a functional impression during tomographic scanning or by the implant region, although deviations were still observed. Further studies are necessary to evaluate the potential benefits of this approach in specific clinical scenarios.
Abstract
INTRODUCTION: Deviations between virtually planned and placed implants are still reported in guided implant surgery in completely edentulous arches. Associating a functional impression with the tomographic guide may enhance guide retention and reduce deviations. This study evaluated the effect of using a functional impression during tomographic image acquisition on the accuracy of implant placement in the edentulous maxilla. METHODS: Fourteen 3D-printed edentulous maxillary models were fabricated. A complete denture was designed and printed for use as a tomographic guide for each model. During dual-scan image acquisition, the experimental group's tomographic guides were seated with a light-body silicone functional impression, whereas the control group was scanned without impression material (n=7). After image registration in Blue Sky Plan software, implants were virtually planned, and surgical guides were printed for the placement of six implants per model. Postoperative scans were obtained, and STL files of planned and placed implants were superimposed to measure linear and angular deviations. Statistical analysis was performed using two-way ANOVA for functional impression and implant region (α=0.05). RESULTS: No statistically significant differences were found regarding the effects of functional impression or implant position (P>0.05) on apical linear (2.11-3.25 mm), coronal linear (1.41-2.06 mm), or angular deviations (5.82-7.27°). CONCLUSION: The accuracy of implant positioning in edentulous maxillae was not significantly affected by the incorporation of a functional impression during tomographic scanning or by the implant region, although deviations were still observed. Further studies are necessary to evaluate the potential benefits of this approach in specific clinical scenarios.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effect of a stackable scanning guide, intraoral scanner type, and operator on the accuracy of maxillary full-arch implant scans: An in vitro studyJournal of Dentistry · 2026
- Accuracy of an innovative extraction socket-supported guide for immediate anterior implantation: An in vitro study.Journal of prosthodontics : official journal of the American College of Prosthodontists · 2026
- Accuracy of digital surgical guides for dental implant placement: A systematic review, meta-analysis and region-specific analysis of the anterior maxilla.International journal of oral implantology (Berlin, Germany) · 2026
- Does manufacturing specialization matter? Transfer accuracy of static surgical guides produced by general-purpose and dental-specific additive workflows: A paired in vitro study.Journal of clinical and experimental dentistry · 2026
- In Vivo Complete Arch Implant Impressions: Comparison of the Linear Precision of Digital and Conventional TechniquesInternational Dental Journal · 2026
- Accuracy of Computer-Guided Dental Implant Placement: A Clinical Comparison of Three Surgical Guide TypesJournal of Clinical Medicine · 2025