AI-Driven CT Analysis for Aortic Disease: A Task-Based Systematic Review of Segmentation, Measurement, and Detection Applications.
Francesco Paparo, Nicola Panvini, Enrico Francesco Melani, Marco Magliocco, Giuseppe Cittadini, Lucio Molini, Giovanni Pratesi, Giovanni Spinella
Radiology Unit, Department of Diagnostic Imaging, E.O. Ospedali Galliera, Mura delle Cappuccine 14, 16128 Genoa, Italy. · Department of Experimental Medicine (DIMES), University of Genoa, 16132 Genoa, Italy.
Key points
From the paper's conclusion- This task-based systematic review synthesised AI applications to CT/CTA of the thoracic and abdominal aorta by primary task: segmentation, measurement, or detection and classification.
Abstract
Background/Objectives: Computed tomography (CT) and CT angiography (CTA) are central to assessing aortic aneurysm and dissection, but manual segmentation and geometric analysis remain time-consuming and operator-dependent, while evidence on artificial intelligence (AI) is fragmented. This task-based systematic review synthesised AI applications to CT/CTA of the thoracic and abdominal aorta by primary task: segmentation, measurement, or detection and classification. Methods: PubMed/MEDLINE and Europe PMC were searched from 2015 to September 2026 following PRISMA 2020; the protocol was registered retrospectively (INPLASY2026110004). Segmentation and measurement studies were appraised with CLAIM and detection studies with QUADAS-2/QUADAS-AI, and results were synthesised without meta-analysis. Results: Of 118 included studies (42 segmentation, 38 measurement, 38 detection), half were published since 2024. Median Dice similarity coefficient was 0.90 or higher for the outer wall, lumen and true and false lumina, but 0.86 for intraluminal thrombus and 0.63 for false lumen thrombus. Automated maximum diameter showed a median absolute bias of 0.26 mm (95% limits of agreement about ±5 mm). Detection of aortic dissection reached a median AUC of 0.96-0.97, mostly in enriched samples. External validation was reported in 14%, 34% and 55% of segmentation, measurement and detection studies, 33 of 38 detection studies were at high risk of bias, and only two systems were evaluated prospectively. Conclusions: AI supports technical automation of aortic CT/CTA segmentation and measurement and is progressing toward multistructure geometric phenotyping and clinical decision support, but independent multicentre validation, consecutive cohorts and prospective reader-in-the-loop studies are required before clinical integration. Detection/classification tools require independent diagnostic and workflow validation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Deep learning versus radiologists for acute aortic dissection on CT: A systematic review and network meta-analysis.European journal of radiology · 2026
- Artificial intelligence–based fully automated multi-class segmentation of aortic dissection in computed tomography imagesEuropean Heart Journal · 2026
- TotalSegmentator Aorta Report: Automated Aortic Diameter Measurement at 11 Standardized Landmarks on CT ImagesarXiv · 2026
- Artificial Intelligence in 3D Aortic CTA Segmentation for Abdominal Aortic Aneurysm Management: A Narrative Review.Journal of imaging · 2026
- Artificial Intelligence for Computer-Aided Detection in Endovascular Interventions: Clinical Applications, Validation, and Translational PerspectivesBioengineering · 2026
- Evaluation of clinical performance of artificial intelligence-assisted measurement of thoracic aortic diameter on non-contrast CT.Medicine · 2026