Evaluation of clinical performance of artificial intelligence-assisted measurement of thoracic aortic diameter on non-contrast CT.
Akiyoshi Suzuki, Nobuo Tomizawa, Kotaro Yamamoto, Yuichi Morita, Shohei Fujita, Katsuhiro Sano, Toshiaki Akashi, Mitsuo Nishizawa,
Department of Radiology, Juntendo University Graduate School of Medicine, Tokyo, Japan. · Department of Cardiovascular Surgery, Juntendo University Graduate School of Medicine, Tokyo, Japan.
Key points
From the paper's conclusion- This study aimed to evaluate the clinical performance of artificial intelligence (AI)-assisted measurement of thoracic aortic diameter on non-contrast computed tomography (NCCT).
Abstract
This study aimed to evaluate the clinical performance of artificial intelligence (AI)-assisted measurement of thoracic aortic diameter on non-contrast computed tomography (NCCT). This single-center prospective study included 79 patients (mean age = 70 ± 13 standard deviation; 46 men) who underwent NCCT and arterial phase contrast-enhanced computed tomography (CECT) for evaluating aortic diseases between 2021 and 2022. Maximum diameters of 9 American Heart Association landmarks and the maximum ascending/descending aorta were measured. Upper limits of the 95% confidence interval (CI) for the absolute difference in aortic diameter between the AI-assisted/manual method on NCCT and the manual method on CECT (DiffAI-assisted/Diffmanual) were calculated and compared using a predefined cutoff of 1.5 mm. Evaluation times were also compared. No significant difference was found between per-patient DiffAI-assisted and Diffmanual (1.10 mm; 95% CI = 1.03-1.18 vs 1.03 mm; 95% CI = 0.95-1.11, P = .058); the upper limit of the 95% CI was <1.5 mm. The upper limit of the 95% CI of the geometric mean DiffAI-assisted and Diffmanual was also <1.5 mm at each landmark. The median evaluation time of the AI-assisted method was shorter than that of the manual method (expert radiologist = 272 seconds [interquartile range (IQR) = 229-313] vs 496 seconds [IQR = 438-550]; P < .001, training radiologist: 304 seconds [IQR = 257-404] vs 710 seconds [IQR = 563-855]; P < .001). AI-assisted thoracic aortic diameter measurement on NCCT was as accurate as manual measurement on CECT; its evaluation time was shorter than that of manual measurement on NCCT.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- AI-based Framework for Automated Segmentation and Surgical Decision Support in Ascending Thoracic Aortic Aneurysm.IEEE journal of biomedical and health informatics · 2026
- AI-Driven CT Analysis for Aortic Disease: A Task-Based Systematic Review of Segmentation, Measurement, and Detection Applications.Tomography (Ann Arbor, Mich.) · 2026
- Artificial intelligence-enhanced multimodality imaging of the aortic root and ascending aortaEuropean Heart Journal · 2026
- Real-life clinical validation of artificial intelligence-assisted echocardiography for aortic root and left ventricular outflow tract measurements against human readers and cardiac magnetic resonance.European heart journal. Digital health · 2026
- AI-based pulmonary artery to ascending aorta ratio on non-contrast CT for pulmonary hypertension: diameter vs. volume assessment.European heart journal. Imaging methods and practice · 2026
- Artificial Intelligence in 3D Aortic CTA Segmentation for Abdominal Aortic Aneurysm Management: A Narrative Review.Journal of imaging · 2026